Nonlinear Parameter and State Estimation Approach for Intradialytic Measurement of Absolute Blood Volume
Abohtyra, R.; Vincent, T.; Schneditz, D.
Show abstract
BackgroundManaging blood and fluid volumes in chronic kidney disease (CKD) patients plays an essential role in dialysis therapy to replace kidney function. ObjectiveThis study aims to develop an estimation approach to provide predictable information on blood and fluid volumes during a regular dialysis routine. MethodsThe method utilizes a non-linear fluid volume model, an optimization technique, and the Unscented Kalman Filter (UKF). This method does not rely on specific ultrafiltration and dilution protocols and uses the Fisher information matrix to quantify the estimation error. ResultsThe method was applied to 21 data sets of ten patients. A significant moderate correlation was obtained when estimated blood volumes were compared to a different method applied to the same data set. Average specific blood volumes were plausible and in the range of 78.7 and 75.9 mL/kg at the end of the high ultrafiltration rate pulse and above the critical level of 65 mL/kg. Critical blood volumes were only observed in four studies done on three patients. ConclusionThe absolute blood volume estimated at the beginning and during every dialysis session offers the opportunity to detect critical blood volumes and to improve fluid management in CKD patients significantly.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- A mathematical model of potassium homeostasis: Effect of feedforward and feedback controls 94%
- Hierarchical semantic composition of biosimulation models using bond graphs 93%
- Design and execution of a Verification, Validation, and Uncertainty Quantification plan for a numerical model of left ventricular flow after LVAD implantation 93%
Similar papers in this journal
- Fluid-structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements 92%
- ATP diffusional gradients are sufficient to maintain bioenergetic homeostasis in synaptic boutons lacking mitochondria 92%
- Validation of a Microfluidic Device Prototype for Cancer Detection and Identification: Circulating Tumor Cells Classification Based on Cell Trajectory Analysis Leveraging Cell-Based Modeling and Machine Learning 91%
Similar papers in this journal
- Comparing physiological impacts of positive pressure ventilation versus self-breathing via a versatile cardiopulmonary model incorporating a novel alveoli opening mechanism 94%
- Improving irregular temporal modeling by integrating synthetic data to the electronic medical record using conditional GANs: a case study of fluid overload prediction in the intensive care unit 93%
- Red blood cell passage through deformable interendothelial slits in the spleen: Insights into splenic filtration and hemodynamics 92%
Similar papers in this journal
- Machine learning for classifying chronic kidney disease and predicting creatinine levels using at-home measurements 94%
- A 1D Model Characterizing the Role of Spatiotemporal Contraction Distributions on Lymph Transport 93%
- Calculating the optimal hematocrit under the constraint of constant cardiac power 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.