Routine surveillance of kidney allograft rejection using a fully automated urinary CXCL9 and CXCL10 immunoassay
Tinel, C.; Sauvaget, V.; Aouni, L.; Lamarthee, B.; Leclaire, C.; Legendre, C.; Marquet, P.; Normand, C.; Rabant, M.; Terzi, F.; Anglicheau, D.
Show abstract
BackgroundFor kidney transplant recipients, assessing non-invasively the individualized risk of acute rejection is one of the most unmet need. Urinary chemokines are one of the short-term most promising biomarkers, because of their simple and low-cost analytical method in easily accessible samples, and their high diagnostic performance consistently assessed over the last decade. In this study, we aimed at confronting all practical issues of routine implementation of kidney allograft rejection monitoring using urine CXCL9 and CXCL10. MethodsThe next-generation immunoassay Ella(R) was investigated as feasible quantification platform, from sample collection to render of the results. Urine CXCL9/10 levels were measured using Ella(R) microfluidic cartridges, across preanalytical (sample preparation, storage conditions, freeze-thaw cycles) and analytical (linearity, ranges, intra/inter-assay variability) performances studies, and diagnostic accuracy was assessed in comparison to the ELISA reference method, in urine samples from previously published cohorts. ResultsUpon assay preparation, Ella(R) appeared very efficient with a minimal workflow (urine sample thaw> centrifugation>1:2 dilution>loading) and a time to result of 90 minutes. Preanalytical studies showed high stability of urine CXCL9/10 levels across various temperatures (4{degrees} vs 25{degrees}C) and time (24/48/72H) before storage and over 5 freeze-thaw cycles. How complex urine matrix, analytical studies confirmed excellent linearity of dosage, as well as intra-assay ([≤]5%) and inter-assay precision. Across 1024 samples, Ella(R) results were highly correlated to those quantified by ELISA (P<0.0001), and further entered into our previously validated urine chemokine model. 268 out of the 1024 samples were collected at time of acute rejection (26.2%). In this cohort, accuracy was 0.85 for acute rejection diagnosis. ConclusionElla(R) fulfils all prerequisites for clinical implementation of urinary chemokines monitoring. It has proven a robust, easy-to-use platform with unprecedented validation to quantify urine chemokines.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Urinary cell mRNA Profiling of Kidney Allograft Recipients: A Systematic Investigation of a Filtration Based Protocol for the Simplification of Urine Processing 95%
- Urinary cell mRNA profiling of kidney allograft recipients: Development of a portable protocol for noninvasive diagnosis of T cell mediated rejection and BK virus nephropathy 94%
- Performance and validation of an adaptable multiplex assay for detection of serologic response to SARS-CoV-2 infection or vaccination 91%
Similar papers in this journal
- Evidence for SARS-CoV-2 Spike Protein in the Urine of COVID-19 patients 94%
- Packed Red Blood Cell and Whole Blood Perfusates during an Ex-vivo Normothermic Perfusion for Assessment of High-Risk Donor Kidneys 93%
- Development and Validation of a Web-based Prediction Model for Acute Kidney Injury after surgery 92%
Similar papers in this journal
Similar papers in this journal
- A precision medicine approach uncovers a unique signature of neutrophils in patients with brushite kidney stones 91%
- Urine Test Predicts Kidney Injury and Death in COVID-19 91%
- A new approach to recognize term and preterm infants with impaired kidney function (IKF) during the first week of life. 91%
Similar papers in this journal