Continuous respiratory rate monitoring using photoplethysmography technology in patients with Obstructive Sleep Apnea
Gehring, J. M.; Saeijs-van Niel, L. C.; ten Bosch-Paniagua, L. P.; Frank, M. H.
Show abstract
PurposeRespiratory rate is an important physiological parameter whose abnormality could be, in the presence of other suggestive symptoms, supportive of a diagnose of various serious illnesses. Photoplethysmography (PPG) in wearable sensors potentially plays an important role in early disease detection by making respiratory rate measurements more accessible. We investigated the accuracy of a new non-invasive, continuous, wrist-worn and wireless monitoring PPG device (Corsano CardioWatch 287) in measuring respiratory rate (RR) and heart rate (HR) at rest. MethodsSubjects with and without diagnosed Obstructive Sleep Apnea (OSA) underwent simultaneous, continuous PPG and home sleep apnea testing (HSAT) for one night. We assessed the PPG sensors measurement accuracy by calculating root-mean-square accuracy (Arms) and by performing Bland Altman and correlation analysis. Subgroups were defined based on skin type, hair density, age, BMI, gender and OSA severity. ResultsIn 26 participants a total of 31083 RR and 38693 HR measurement pairs were obtained. For RR measurements, Arms was 0.60 breaths per minute (brpm). Correlation was high (r = 0.964 (95%CI 0.963 - 0.965)) and 95% Limits of Agreement (LoA) were -1.28 to 1.71 brpm (mean bias -0.14 brpm). For HR measurements, Arms was 0.95 beats per minute (bpm). Correlation was similarly high (r = 0.996 (95%CI 0.996 - 0.996) and 95% LoA were - 2.09 to 1.17 bpm (mean bias -0.46 bpm). Results were comparable across all subgroups, without significant difference in RR accuracy between subjects with and without diagnosed OSA. In free-living conditions, Arms was 2.43 brpm and 95% LoA were -5.00 to 4.47 brpm (mean bias -0.27 brpm). ConclusionWe showed that the Corsano Cardiowatch 287 using PPG technology can monitor continuous RR and HR with high accuracy in healthy subjects as well as in patients diagnosed with OSA. We conclude that wearable devices like these enable new and more accessible ways to measure health, ultimately improving healthcare delivery. The trial was registered in the ISCRTN registry under reference ISRCTN13965929.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Is sleep apnea-hypopnea index relevant for impaired brain perfusion and desaturation in patients with severe obstructive sleep apnea syndromes? 97%
- Novel Digital Markers of Sleep Dynamics: A Causal Inference Approach Revealing Age and Gender Phenotypes in Obstructive Sleep Apnea 93%
- The relationship between subjective sleep quality and cognitive performance in healthy young adults: Evidence from three empirical studies 93%
Similar papers in this journal
- Correlation analysis of heart rate variations and glucose fluctuations during sleep 96%
- Obstructive sleep apnea is highly prevalent in COVID19 moderate to severe ARDS survivors: Findings of level I Polysomnography in a tertiary care hospital 96%
- Impact of OSA Treatment Success on Changes in Hypertension and Obesity: A Retrospective Cohort Study 93%
Similar papers in this journal
- Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients 92%
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 90%
- The physiological demands of Singing for Lung Health compared to treadmill walking 90%
Similar papers in this journal