AIM (Angular Indication Measurement) paradigm: Adaptive, self-administered, and generalizable vision assessment used to measure visual acuity
Skerswetat, J.; He, J.; Shah, J. B.; Aycardi, N.; Bex, P. J.
Show abstract
This proof-of-concept study introduces Angular Indication Measurement and applies it to VA (AIM-VA). First, we compared the ability of AIM-VA and ETDRS to detect defocus and astigmatic blur in 22 normally-sighted adults. Spherical and cylindrical lenses ({+/-}0.00D, +0.25D, +0.50D, +0.75D, +1.00D, +2.00D and +0.50D, +1.00D, +2.00D each at 0{degrees}, 90{degrees}, 135{degrees}, respectively) in the dominant eye induced blur. Second, we compared repeatability over two tests of AIM-VA and ETDRS. A 2-way-ANOVA showed a main effect for defocus-blur and test with no interaction. A 3-way-ANOVA for the astigmatism experiment revealed main effects for test type, blur, and direction and with no interactions. Planned multiple comparisons showed AIM had greater astigmatic-induced VA loss than ETDRS. Bland-Altman plots showed small bias and no systematic learning effect for either test type and improved repeatability with >2 adaptive steps for AIM-VA. AIM-VAs ability to detect defocus was comparable with that of an ETDRS letter chart and showed greater sensitivity to astigmatic blur, and AIM-VAs repeatability is comparable with ETDRS when using 2 or more adaptive steps. AIMs self-administered orientation judgment approach is generalizable to interrogate other visual functions, e.g., contrast, color, motion, stereo-vision.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Visual field evaluation using Zippy Adaptive Threshold Algorithm (ZATA) Standard and ZATA Fast in patients with glaucoma and healthy individuals 97%
- Two-Photon Microperimetry: A media opacity-independent retinal function assay 97%
- Relating Standardized Automated Perimetry Performed with Stimulus Sizes III and V in Eyes With Field Loss due to Glaucoma and NAION 96%
Similar papers in this journal
Similar papers in this journal
- The evaluation of a web‐based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: a prospective open‐label method comparison study 96%
- A Normative Database of A-Scan Data Using the Heidelberg Spectralis Spectral Domain Optical Coherence Tomography Machine 95%
- Automated 360-degree goniophotography with the NIDEK Gonioscope GS-1 for glaucoma 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.