Left atrial substrate characterization based on bipolar voltage electrograms acquired with multipolar, focal and mini-electrode catheters- the CHAZE-Substrate study
Knecht, S.; Schlageter, V.; Badertscher, P.; Krisai, P.; Jousset, F.; Spies, F.; Kueffer, T.; Madaffari, A.; Schaer, B.; Osswald, S.; Sticherling, C.; Kühne, M.
Show abstract
BackgroundBipolar voltage (BV) electrograms for left atrial (LA) substrate characterization depend on catheter design and electrode configuration. The aim of the study was to investigate the relationship between the BV amplitude (BVA) using four different catheters and to identify their specific LA cutoffs for scar and healthy tissue. MethodsConsecutive high-resolution electroanatomic mapping was performed using a multipolar Orion catheter (Orion-map), a duo-decapolar variable circular mapping catheter (Lasso-Map) and an irrigated focal ablation catheter with minielectrodes (Mifi-map). Virtual remapping using the Mifi-map was performed with a 4.5 mm tip-size electrode configuration (Nav-map). BVAs were compared in voxels of 3x3x3 mm3. The equivalent BVA cutoff for every catheter was calculated for established reference cutoff values of 0.1 mV, 0.2 mV, 0.5 mV, 1.0 mV, and 1.5 mV. ResultsWe analyzed 25 patients (72% men, age 68{+/-}15 years). For scar tissue, a 0.5 mV cutoff using the Nav corresponds to a lower cutoff of 0.35 mV for the Orion and of 0.48 mV for the Lasso. Accordingly, a 0.2 mV cutoff corresponds to a cutoff of 0.09 mV for the Orion and of 0.14 mV for the Lasso. For a healthy tissue cutoff at 1.5 mV, a larger BVA cutoff for the small electrodes of the Orion and the Lasso was determined of 1.68 mV and 2.21 mV, respectively. ConclusionsWhen measuring LA BVA in scar and healthy tissue, relevant differences were seen between focal, multielectrode and mini-electrode catheters. Adapted cutoffs for scar and healthy tissue are required.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A Novel Temperature Controlled Bipolar Radiofrequency Ablation: An Ex Vivo Study for Optimizing Efficacy and Safety Parameters 97%
- Catheter Ablation Approach Targeting Epicardial Connections to the Right Pulmonary Vein Antrum Detected before Pulmonary Vein Isolation 96%
- Right bundle branch pacing: criteria, characteristics and outcomes 96%
Similar papers in this journal
- Peri-Procedural Intravascular Hemolysis during Atrial Fibrillation Ablation: A Comparison of Pulsed-Field with Radiofrequency Ablation 96%
- Enhancing Ventricular Tachycardia Ablation Outcomes: The Impact Of Functional Mapping In Chagas Cardiomyopathy 96%
- Multicenter analysis of atrioesophageal fistula rates before and after adoption of active esophageal cooling during atrial fibrillation ablation 95%
Similar papers in this journal
- Atrial functional substrates for the prediction of atrial fibrillation recurrence after pulmonary vein isolation 96%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 91%
- Ticagrelor vs Clopidogrel: the Impact of Platelet Inhibition on Cerebrovascular Microembolic Events during TAVR 91%
Similar papers in this journal
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 93%
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 92%
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 92%
Similar papers in this journal
- Transmural and rate-dependent profiling of drug-induced arrhythmogenic risks through in silico simulations of multichannel pharmacology 91%
- Improved evaluation of left ventricular hypertrophy using the spatial QRS-T angle by electrocardiography 91%
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.