Modeling Flow in an In Vitro Anatomical Cerebrovascular Model with Experimental Validation
Bhardwaj, S.; Craven, B. A.; Sever, J. E.; Costanzo, F.; Simon, S. D.; Manning, K. B.
Show abstract
Acute ischemic stroke (AIS) is a leading cause of mortality that occurs when an embolus becomes lodged in the cerebral vasculature and obstructs blood flow in the brain. The severity of AIS is determined by the location and how extensively emboli become lodged, which are dictated in large part by the cerebral flow and the dynamics of embolus migration which are difficult to measure in vivo in AIS patients. Computational fluid dynamics (CFD) can be used to predict the patient-specific hemodynamics and embolus migration and lodging in the cerebral vasculature to better understand the underlying mechanics of AIS. To be relied upon, however, the computational simulations must be verified and validated. In this study, a realistic in vitro experimental model and a corresponding computational model of the cerebral vasculature are established that can be used to investigate flow and embolus migration and lodging in the brain. First, the in vitro anatomical model is described, including how the flow distribution in the model is tuned to match physiological measurements from the literature. Measurements of pressure and flow rate for both normal and stroke conditions were acquired and corresponding CFD simulations were performed and compared with the experiments to validate the flow predictions. Overall, the CFD simulations were in relatively close agreement with the experiments, to within {+/-}7% of the mean experimental data with many of the CFD predictions within the uncertainty of the experimental measurement. This work provides an in vitro benchmark data set for flow in a realistic cerebrovascular model and is a first step towards validating a computational model of AIS.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 97%
- Quantitative Assessment of Aortic Hemodynamics for Varying Left Ventricular Assist Device Outflow Graft Angles and Flow Pulsation 97%
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 96%
Similar papers in this journal
- Effects of size and elasticity on the relation between flow velocity and wall shear stress in side-wall aneurysms: A lattice Boltzmann-based computer simulation study 97%
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 96%
- Mechanics of knee meniscus results from precise balance between material microstructure and synovial fluid viscosity 95%
Similar papers in this journal
- Biomechanical stress analysis of Type-A aortic dissection at pre-dissection, post-dissection, and post-repair states 97%
- Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm 97%
- Fluid-Structure Interactions of Peripheral Arteries Using a Coupled in silico and in vitro Approach 96%
Similar papers in this journal
- Inverse Material Parameter Estimation of Patient Specific Finite Element Models at the Carotid Bifurcation: The Impact of Excluding the Zero Pressure Configuration and Residual Stress 97%
- Generic Framework for Quantifying the Influenceof the Mitral Valve on Ventricular Blood Flow 96%
- Fluid-structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements 96%
Similar papers in this journal
- Experiments and Simulations to Assess Exercise-Induced Pressure Drop Across Aortic Coarctations 96%
- Tuning the Pennes Perfusion Rate to Model Large Vessel Cooling Effects in Hepatic Radiofrequency Ablation 93%
- Stretching the Limits: From Planar-Biaxial Stress-Stretch to Arterial Pressure-Diameter 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.