Impact of patient habitus and acquisition protocol on iodine quantification in dual source photon-counting CT.
Pua, R.; Liu, L. P.; Dieckmeyer, M.; Shapira, N.; Sahbaee, P.; Gang, G. J.; Litt, H.; Noel, P. B.
Show abstract
ObjectiveEvaluation of iodine quantification accuracy with varying iterative reconstruction level, patient habitus, and acquisition mode on a first-generation dual-source photon-counting computed tomography (PCCT) system. MethodsA multi-energy CT phantom (20 cm diameter/small) was imaged with and without an extension ring (30 by 40 cm/large). It was equipped with various iodine inserts (0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0 mg/ml) and scanned over a range of radiation dose levels (CTDIvol 0.5, 0.8, 1.2, 1.6, 2.0, 4.0, 6.0, 10.0, 15.0 mGy) using four different acquisition modes: single source 120 kVp (SS120), 140 kVp (SS140) and dual-source 120 kVp (DS120), 140 kVp (DS140). Iodine density maps were produced with different levels of iterative reconstruction (QIR 0, 2, 4). To assess the agreement between nominal and measured iodine concentrations, root mean square error (RMSE) and Bland-Altman plots were generated by grouping different radiation dose levels (ultra-low: < 1.5 mGy; low: 1.5 - 5 mGy; medium: 5 - 15 mGy) and iodine concentrations (low: < 5 mg/ml; high: 5 - 15 mg/ml). ResultsOverall, quantification of iodine concentrations was accurate and reliable even at ultra-low radiation dose levels. With low and high iodine concentrations, RMSE ranged from 0.25 to 0.37, 0.20 to 0.38, and 0.25 to 0.37 mg/ml for ultra-low, low, and medium radiation dose levels, respectively. Similarly, for the three acquisition modes (SS120, SS140, DS 120, DS140), RMSE was stable at 0.31, 0.28, 0.33 and 0.30 mg/ml, respectively. Considering all levels of radiation dose, acquisition mode, and iodine concentration, the accuracy of iodine quantification was higher for the phantom without extension ring (RMSE 0.21 mg/ml) and did not vary across different levels of iterative reconstruction. ConclusionsThe first-generation PCCT allows for accurate iodine quantification over a wide range of iodine concentrations and radiation dose levels. Even very small concentrations of iodine can be quantified accurately at different simulated patient sizes. Stable accuracy across iterative reconstruction levels may allow further radiation exposure reductions without affecting quantitative results. SummaryClinical photon-counting CT provides excellent iodine quantification performance for a wide range of parameters (patient habitus, acquisition parameters, and iterative reconstruction modes) due to its excellent ultra-low dose performance. Key ResultsFirst-generation PCCTs are capable of accurately quantifying iodine over a wide range of radiation dose levels and iodine concentrations. Further radiation exposure reductions may be possible given stable accuracy across iterative reconstruction levels. In the future, accurate and precise iodine quantification will allow for the development of spectral-based biomarkers.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 97%
- Precise dose verification in proton therapy using Positron Emission Tomography. 96%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 96%
Similar papers in this journal
- Internal calibration for opportunistic computed tomography muscle density analysis 96%
- PET/CT and SPECT/CT imaging of 90 Y hepatic radioembolization at therapeutic and diagnostic activity levels: anthropomorphic phantom study 95%
- Inclusion of a GaAs detector model in the Photon Counting Toolkit software for the study of breast imaging systems 95%
Similar papers in this journal
- Experimental investigation of oxygen diffusion in the peak and valley region of minibeam patterns during X-Ray irradiation 93%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 92%
- Non-Invasive monitoring of normal tissue radiation damage using quantitative ultrasound spectroscopy 92%
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 94%
- Multiwell-based G0-PCC assay for radiation biodosimetry 92%
- Dependence of fluorodeoxyglucose (FDG) uptake on cell cycle and dry mass: a single-cell study using a multi-modal radiography platform 90%
Similar papers in this journal
- Recent advances in the clinical applications of machine learning in proton therapy 93%
- Breast density prediction from low and standard dose mammograms using deep learning: effect of image resolution and model training approach on prediction quality 92%
- Model uncertainty estimates for deep learning mammographic density prediction using ordinal and classification approaches 86%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.