Determinants for detection of infection with SARS-CoV-2 Omicron variants of concern in health care workers by rapid antigen tests
Knolle, P. A.; Wettengel, J.; Strehle, K.; Lucke, C.; Roggendorft, H.; Jeske, S.; Christa, C.; Zelger, O.; Haller, B.; Protzer, U. A.
Show abstract
IMPORTANCEThe rapid genetic evolution of SARS-CoV-2 and in particular the highly contagious Omicron variant of concern (VoC) may pose problems for rapid and accurate diagnosis of infection. OBJECTIVEDetermine the diagnostic accuracy and robustness of a second generation rapid antigen tests compared to gold-standard, PCR-based diagnostics, for detection of infection with different SARS-CoV-2 Omicron VoC sub lineages in health care workers. DESIGN, SETTING, AND PARTICIPANTSThe study included 428 health care workers from the University Hospital Munich Rechts der Isar of the Technical University of Munich who either reported recent onset of COVID-19 associated symptoms or completed routine diagnostic testing between 24th of May and 22nd of September 2022. All participants gave written informed consent to participate in this study and completed a questionnaire on infection-associated symptoms, prior SARS-CoV-2 infections and vaccination status. INTERVENTIONSDuring the first visit, two nasal swabs and one oropharyngeal swab were taken to perform two rapid antigen tests and a SARS-CoV-2 PCR-assay, respectively. A second set of nasal swabs was taken by the participants themselves two days later to repeat the two rapid antigen tests. MAIN OUTCOMES AND MEASURESThe accuracy for detection of infection with different SARS-CoV-2 Omicron VoCs with two rapid antigen tests (Test I and Test II) was determined and compared to quantitative SARS-CoV-2 RNA levels detected by PCR. RESULTSIn a side-by-side comparison, we found that Test I detected viral nucleocapsids from Omicron VoC (BA.5.2.3) at higher dilutions compared to Test II. In the 428 health care workers, Test I and Test II detected PCR-confirmed SARS-CoV-2 infection with different Omicron VoCs (BA.2, BA.4, BA.5) with a sensitivity of 89.4% (95% CI 81.9% - 94.6%) and 83.7% (95% CI 75.12% - 90.18%), respectively. Increased sensitivity of Test I was also reflected by earlier detection of SARS-CoV-2 infection. The lower test sensitivity of Test II could be compensated for by a repeated test performed two days later. CONCLUSIONS AND RELEVANCEOur study demonstrates that rapid antigen tests are suited to detect infection with the SARS-CoV-2 Omicron VoC and reveal an advantage of a lower detection limit for earlier detection of infection in health care workers.
Matching journals
The top 10 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Self-testing for the detection of SARS-CoV-2 infection with rapid antigen tests 96%
- Field evaluation of a rapid antigen test (Panbio™ COVID-19 Ag Rapid Test Device) for the diagnosis of COVID-19 in primary healthcare centers 95%
- Non-occupational and occupational factors associated with specific SARS-CoV-2 antibodies among Hospital Workers – a multicentre cross-sectional study 94%
Similar papers in this journal
- Diagnostic accuracy of two commercial SARS-CoV-2 Antigen-detecting rapid tests at the point of care in community-based testing centers 96%
- Evaluation of the Abbott Panbio™ COVID-19 antigen detection rapid diagnostic test among healthcare workers in elderly care 96%
- Evaluation of the accuracy and ease-of-use of Abbott PanBio - A WHO emergency use listed, rapid, antigen-detecting point-of-care diagnostic test for SARS-CoV-2 96%
Similar papers in this journal
- Comparison between mid-nasal swabs and buccal swabs for SARS-CoV-2 detection in mild COVID-19 patients 96%
- Evaluation of the Panbio™ rapid antigen test for SARS-CoV-2 in primary health care centers and test sites 96%
- Performance characteristics of five antigen-detecting rapid diagnostic test (Ag-RDT) for SARS-CoV-2 asymptomatic infection: a head-to-head benchmark comparison 95%
Similar papers in this journal
- Investigating sensitivity of nasal or throat (ISNOT): A combination of both swabs increases sensitivity of SARS-CoV-2 rapid antigen tests 96%
- Evaluation of the INDICAID™ COVID-19 Rapid Antigen Test in symptomatic populations and asymptomatic community testing 95%
- Serological testing reveals the hidden COVID-19 burden among healthcare workers experiencing a SARS-CoV-2 nosocomial outbreak 95%
Similar papers in this journal
- Longitudinal testing for respiratory and gastrointestinal shedding of SARS-CoV-2 in day care centres in Hesse, Germany. Results of the SAFE KiDS Study 95%
- The New Normal: Delayed Peak SARS-CoV-2 Viral Loads Relative to Symptom Onset and Implications for COVID-19 Testing Programs 94%
- Antigen-based testing but not real-time PCR correlates with SARS-CoV-2 virus culture 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.