Stability of spectral results in cardiac dual-source photon-counting CT
Liu, L. P.; Shapira, N.; Sahbaee, P.; Gang, G. J.; Knollman, F. D.; Chen, M. Y.; Litt, H. I.; Noël, P. B.
Show abstract
ObjectiveEvaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). Materials and MethodsA cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned with a first-generation dual-source PCCT at five different heart rates (0, 60, 70, 80, 100 bpm). Scans were performed at 120 kVp with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, virtual monoenergetic images at 50, 70, and 150 keV and iodine density maps were reconstructed at both diastole and systole to investigate the effect of the cardiac phase. Full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were analyzed. ResultsFWHM exhibited average differences from the static FWHM across cardiac phase and heart rates of -0.20, -0.28, and -0.15 mm at VMI 150 keV for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with larger differences present at systole and with high pitch scans. Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result. ConclusionsConsistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 95%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 93%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 93%
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 96%
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 94%
- Reproducibility of 4D Flow MRI-based Personalized Cardiovascular Models; Inter-sequence, Intra-observer, and Inter-observer variability 93%
Similar papers in this journal
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 96%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 96%
- Contrast-enhanced photon-counting micro-CT of tumor xenograft models 94%
Similar papers in this journal
- First-generation clinical dual-source photon-counting CT: ultra-low dose quantitative spectral imaging 97%
- Impact of Non-Contrast Enhanced Imaging Input Sequences on the Generation of Virtual Contrast-Enhanced Breast MRI Scans using Neural Networks 94%
- From Community Acquired Pneumonia to COVID-19: A Deep Learning Based Method for Quantitative Analysis of COVID-19 on thick-section CT Scans 92%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.