Novel 10-channel phased-array coil design for carotid wall MRI at 3T
de Buck, M. H. S.; Jezzard, P.; Frost, R.; Randell, C.; Hurst, K.; Choudhury, R. P.; Robson, M. D.; Biasiolli, L.
Show abstract
BackgroundAccurate assessment of plaque accumulation near the carotid bifurcation is important for the effective prevention and treatment of stroke. However, vessel and plaque delineation using MRI can be limited by low contrast-to-noise ratio (CNR) and long acquisition times. In this work, a novel 10-channel phased-array receive coil design for bilateral imaging of the carotid bifurcation using 3T MRI is proposed. MethodsThe novel 10-channel receive coil was compared to a commercial 4-channel receive coil configuration using data acquired from phantoms and healthy volunteers (N = 9). The relative performance of the coils was assessed, by comparing signal-to-noise ratio (SNR), g-factor noise amplification, and the CNR between vessel wall and lumen using black-blood sequences. Patient data were acquired from 12 atherosclerotic carotid artery disease patients. ResultsThe 10-channel coil consistently provided substantially increased SNR in phantoms (+88 {+/-} 2%) and improved CNR in healthy carotid arteries (+62 {+/-} 11%), or reduced g-factor noise amplification. Patient data showed excellent delineation of atherosclerotic plaque along the length of the carotid bifurcation using the 10-channel coil. ConclusionsThe proposed 10-channel coil design allows for improved visualization of the carotid arteries and the carotid bifurcation and increased parallel imaging acceleration factors.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Combined Angiographic, Structural and Perfusion Radial Imaging using Arterial Spin Labeling 96%
- Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study 96%
- Quantitative susceptibility mapping of carotid arterial tissue ex vivo: assessing sensitivity to vessel microstructural composition 96%
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 94%
- A Phantom System Designed to Assess the Effects of Membrane Lipids on Water Proton Relaxation 93%
- 31P Transversal Relaxation Times and Metabolite Concentrations in the Human Brain at 9.4T 93%
Similar papers in this journal
- Does contrast-enhancement improve visualisation of lenticulostriate arteries in cerebral small vessel disease using time-of-flight magnetic resonance angiography at 7 Tesla? 95%
- Temporal signal-to-noise changes in combined multiband- and slice-accelerated echo-planar imaging with a 20- and 64-channel coil 94%
- Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas 94%
Similar papers in this journal
- A novel model to quantify blood transit time in cerebral arteries using ASL-based 4D magnetic resonance angiography with example clinical application in moyamoya disease 95%
- 2-deoxy-D-glucose chemical exchange-sensitive spin-lock MRI of cerebral glucose metabolism after stroke in the rat 93%
- Optimal filtering strategies for task-specific functional PET imaging 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.