Back

Comparison of Peripheral Blood Oxygen Saturation Measurements Using Pulse Oximetry at Three Anatomical Sites on Sleep Patients

Strickland, K. R.; Brown, C. J.; Wilks, L. K.; Dunn, P. K.; Holmes, M. A.

2022-09-09 respiratory medicine
10.1101/2022.09.08.22279707 medRxiv
Show abstract

Background and ObjectiveAccurate measurements of peripheral blood oxygen saturation (SpO2) are important in evaluating sleep patients with frequent desaturations due to pathological breathing events. This project compared synchronised SpO2 measurements at the finger, forehead and toe of patients undergoing Type 1 polysomnography (PSG) to evaluate potential SpO2 variability across the sites. MethodsPulse oximetry SpO2 measurements were simultaneously and continuously recorded for 41 sleep patients at the finger, forehead and toe, and synchronised with PSG data. Recordings were scored for desaturations of [&le;] 3% (peak to trough, lasting [&le;]10 seconds), signal dropouts, and artefact occurrences. Forehead and toe SpO2 measurements were compared against the finger as the standard PSG oximetry site. ResultsDifferences between anatomical sites for mean SpO2, mean number of SpO2 desaturations per hour, and time spent below an SpO2 level of 95% during total sleep time were significant (P < 0.01). The forehead pulse oximeter had the highest mean SpO2, least number of SpO2 desaturations per hour, and experienced the least number of artefact occurrences. Dropouts were lowest for the forehead and toe pulse oximeters. ConclusionDifferences between SpO2 measurements, dropouts and artefact occurrences at the finger, forehead and toe may have diagnostic and prognostic implications for sleep patients. The differences in SpO2 measurements may be attributed to variability in perfusion of the extremities and core during sudden oscillating blood pressure changes associated with breathing events. Further research is required to determine which anatomical site correlates closest to arterial oxygenation for pulse oximetry in sleep patients. BRIEF SUMMARYO_ST_ABSStudy rationaleC_ST_ABSAn absence of research investigating anatomical site location for pulse oximetry during overnight polysomnography exists. Our study was performed to fill this gap, as accurate pulse oximetry measurements are key for the diagnosis, treatment and monitoring of sleep patients; a patient cohort where SpO2 desaturations are recurrent. Study impactOur findings demonstrate there are significant differences between finger, forehead and toe pulse oximetry measurements, particularly SpO2 desaturations per hour, which may have diagnostic and clinical implications. This research is applicable and important to not only sleep physicians and scientists, but also other disciplines where continuous SpO2 monitoring is required.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
Sleep Medicine
18 papers in training set
Top 0.1%
23.3%
2
BMJ Open
554 papers in training set
Top 1%
15.2%
3
PLOS ONE
4510 papers in training set
Top 21%
8.7%
4
Scientific Reports
3102 papers in training set
Top 16%
6.5%
50% of probability mass above
5
Frontiers in Physiology
93 papers in training set
Top 0.5%
6.5%
6
Journal of Sleep Research
31 papers in training set
Top 0.1%
5.0%
7
BMJ Open Respiratory Research
32 papers in training set
Top 0.2%
4.5%
8
Sleep
26 papers in training set
Top 0.3%
2.0%
9
Annals of Clinical and Translational Neurology
29 papers in training set
Top 0.5%
1.8%
10
JMIR Formative Research
32 papers in training set
Top 0.7%
1.8%
11
Journal of Medical Internet Research
85 papers in training set
Top 3%
1.3%
12
Frontiers in Neurology
91 papers in training set
Top 4%
1.3%
13
Medical Research Archives
11 papers in training set
Top 0.3%
1.3%
14
International Journal of Environmental Research and Public Health
124 papers in training set
Top 5%
1.3%
15
Frontiers in Pediatrics
29 papers in training set
Top 0.6%
1.0%
16
Journal of Applied Physiology
29 papers in training set
Top 0.4%
1.0%
17
Brain Sciences
52 papers in training set
Top 1%
0.9%
18
JMIRx Med
31 papers in training set
Top 1%
0.9%
19
JMIR mHealth and uHealth
10 papers in training set
Top 0.4%
0.8%
20
BMC Medicine
163 papers in training set
Top 6%
0.8%
21
iScience
1063 papers in training set
Top 30%
0.8%
22
Frontiers in Endocrinology
53 papers in training set
Top 2%
0.8%
23
Royal Society Open Science
193 papers in training set
Top 5%
0.7%
24
Systematic Reviews
11 papers in training set
Top 0.7%
0.5%
25
Cureus
67 papers in training set
Top 6%
0.5%
26
BJGP Open
12 papers in training set
Top 0.8%
0.5%