Comparison of Peripheral Blood Oxygen Saturation Measurements Using Pulse Oximetry at Three Anatomical Sites on Sleep Patients
Strickland, K. R.; Brown, C. J.; Wilks, L. K.; Dunn, P. K.; Holmes, M. A.
Show abstract
Background and ObjectiveAccurate measurements of peripheral blood oxygen saturation (SpO2) are important in evaluating sleep patients with frequent desaturations due to pathological breathing events. This project compared synchronised SpO2 measurements at the finger, forehead and toe of patients undergoing Type 1 polysomnography (PSG) to evaluate potential SpO2 variability across the sites. MethodsPulse oximetry SpO2 measurements were simultaneously and continuously recorded for 41 sleep patients at the finger, forehead and toe, and synchronised with PSG data. Recordings were scored for desaturations of [≤] 3% (peak to trough, lasting [≤]10 seconds), signal dropouts, and artefact occurrences. Forehead and toe SpO2 measurements were compared against the finger as the standard PSG oximetry site. ResultsDifferences between anatomical sites for mean SpO2, mean number of SpO2 desaturations per hour, and time spent below an SpO2 level of 95% during total sleep time were significant (P < 0.01). The forehead pulse oximeter had the highest mean SpO2, least number of SpO2 desaturations per hour, and experienced the least number of artefact occurrences. Dropouts were lowest for the forehead and toe pulse oximeters. ConclusionDifferences between SpO2 measurements, dropouts and artefact occurrences at the finger, forehead and toe may have diagnostic and prognostic implications for sleep patients. The differences in SpO2 measurements may be attributed to variability in perfusion of the extremities and core during sudden oscillating blood pressure changes associated with breathing events. Further research is required to determine which anatomical site correlates closest to arterial oxygenation for pulse oximetry in sleep patients. BRIEF SUMMARYO_ST_ABSStudy rationaleC_ST_ABSAn absence of research investigating anatomical site location for pulse oximetry during overnight polysomnography exists. Our study was performed to fill this gap, as accurate pulse oximetry measurements are key for the diagnosis, treatment and monitoring of sleep patients; a patient cohort where SpO2 desaturations are recurrent. Study impactOur findings demonstrate there are significant differences between finger, forehead and toe pulse oximetry measurements, particularly SpO2 desaturations per hour, which may have diagnostic and clinical implications. This research is applicable and important to not only sleep physicians and scientists, but also other disciplines where continuous SpO2 monitoring is required.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Obstructive sleep apnea is highly prevalent in COVID19 moderate to severe ARDS survivors: Findings of level I Polysomnography in a tertiary care hospital 97%
- Correlation analysis of heart rate variations and glucose fluctuations during sleep 95%
- Neither fifty percent slow-wave sleep suppression nor fifty percent rapid eye movement sleep suppression does impair memory consolidation 94%
Similar papers in this journal
- Quantitative detection of sleep apnea with wearable watch device 97%
- A single nucleotide polymorphism in the HOMER1 gene is associated with sleep latency and theta power in sleep electroencephalogram 95%
- Improved Sleep, Cognitive Processing and Enhanced Learning and Memory Task Accuracy with Yoga Nidra Practice in Novices 95%
Similar papers in this journal
- Is sleep apnea-hypopnea index relevant for impaired brain perfusion and desaturation in patients with severe obstructive sleep apnea syndromes? 97%
- Topographical relocation of adolescent sleep spindles reveals a new maturational pattern of the human brain 93%
- The relationship between subjective sleep quality and cognitive performance in healthy young adults: Evidence from three empirical studies 92%
Similar papers in this journal
- Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients 92%
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 89%
- A new method to measure inter-breath intervals in infants for the assessment of apnoea and respiratory dynamics 88%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.