Evaluation of different diffusion-weighted image techniques for head and neck radiation treatment: phantom and volunteer studies
Joint Head, Neck Radiation Therapy-MRI Development Cooperative, ; Ding, Y.; Meheissen, M. A. M.; Zhou, K.; Mohamed, A. S. R.; Wen, Z.; Ng, S. P.; Elhalawani, H. M.; Elgohari, B. A.; Hutcheson, K. A.; Chung, C.; Lai, S. Y.; Fuller, C. D.; Wang, J.
Show abstract
PurposeTo quantitatively compare and assess the geometric distortion and apparent diffusion coefficient (ADC) accuracy of conventional single-shot EPI (SSEPI)-DWI, readout segmentation of long variable echo-trains (RESOLVE)-DWI, and BLADE-DWI techniques in both phantom and volunteer imaging studies. MethodsPhantom measurements were obtained using the QIBA DWI phantom at 0{degrees} and at ambient temperature (~17{degrees}). DW images were acquired using SSEPI-DWI, RESOLVE-DWI, and BLADE-DWI. Image geometric distortion factors (compression and dilation, shear distortion), and image shift factors were measured and compared with computed tomography images. ADC and signal-to-noise ratio (SNR) values were measured for the various DWI techniques. Images were also obtained from three healthy volunteers and three oropharynx cancer patients. Geometric distortion parameters and ADC values were analyzed in the following head and neck regions of interest (ROI): salivary glands, tonsils, and primary tumors (patient only). The metric evaluation included Dice similarity coefficient and Hausdorff distance mean. T2-weighted images were used as a reference to evaluate geometric distortion. ResultsIn the phantom experiment, the vials were prominently distorted on the SSEPI-DWI and RESOLVE-DWI images but were less distorted on the BLADE-DWI image, as determined by the overall effects of Image geometric distortion factors. The paired t-test showed no significant difference (0.15 < p < 0.88) in ADC values among the three DWI techniques; however, BLADE-DWI led to a lower SNR in vials. In the volunteer and patient studies, an ROI-based overlap metrics analysis of the salivary glands and gross tumor volumes were less distorted for BLADE-DWI than for EPI-based DWI, as determined by Wilcoxon paired signed-rank test. ConclusionBLADE-DWI demonstrated excellent geometric accuracy, with similar quantitative ADC values to those of EPI-based DW-MRI, thus potentially making this technique suitable for target volume delineation and functional assessment for head and neck radiation treatment in the future.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting improves intravoxel incoherent motion (IVIM) analysis in the human kidney 94%
- Investigation of diffusion time dependence of apparent diffusion coefficient and intravoxel incoherent motion parameters in the human kidney 94%
- Real-time Imaging of Decompression Gas Bubble Growth in the Spinal Cord of Live Rats 93%
Similar papers in this journal
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 96%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 95%
- Deep learning-based auto-segmentation of swallowing and chewing structures 94%
Similar papers in this journal
- Quality Assurance Assessment of Intra-Acquisition Diffusion-Weighted and T2-Weighted Magnetic Resonance Imaging Registration and Contour Propagation for Head and Neck Cancer Radiotherapy 96%
- PSMA-Hornet: fully-automated, multi-target segmentation of healthy organs in PSMA PET/CT images 93%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 93%
Similar papers in this journal
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 94%
- Association of Graph-based Spatial Features with Overall Survival Status of Glioblastoma Patients 94%
- Correcting B0 inhomogeneity-induced distortions in whole-body diffusion MRI of bone metastases 93%
Similar papers in this journal
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 94%
- Improved characterization of diffusion in normal and cancerous prostate tissue through optimization of the restriction spectrum imaging signal model 93%
- Test-retest reproducibility of in vivo magnetization transfer ratio and saturation index in mice at 9.4 Tesla 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.