Adaptive Magnetic Resonance
Beracha, I.; Seginer, A.; Tal, A.
Show abstract
Nuclear magnetic resonance is one of the cornerstones of modern medicine and biomedical research. Over the past several decades, the speed and precision of in-vivo magnetic resonance imaging (MRI) and spectroscopy (MRS) have increased by leaps and bounds, by utilizing sophisticated excitation and acquisition techniques, from parallel imaging and compressed sensing to magnetic resonance fingerprinting. However, these approaches have all been static in nature, fixing measurement parameters in advance, in anticipation of a wide range of expected tissue parameter values, and are therefore sub-optimal for any given subject. We depart from the conventional framework of magnetic resonance and propose a new approach - termed adaptive magnetic resonance - which binds acquisition and excitation, by using the measured signal to update and fine-tune the measurement parameters in real time. This targets the specific tissue characteristics of the subject while they are being scanned. Adaptive magnetic resonance provides a completely new and previously-untapped avenue for improving the sensitivity and specificity of in-vivo magnetic resonance across all tissue contrast mechanisms. Equivalently, it can accelerate data acquisition compared to non-adaptive schemes, by obtaining the same precision using fewer, optimally tuned excitations. We demonstrate that an adaptive pulse sequence for measuring the transverse relaxation time (T2) of metabolites in-vivo improves upon the precision of static approaches by a factor of {approx} 1.7 - or, alternatively, accelerates acquisition 2.5-fold.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Identifying out-of-voxel echoes in edited MRS with phase cycle inversion 98%
- QSM Reconstruction Challenge 2.0: a realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures 98%
- Multi-echo Quantitative Susceptibility Mapping: How to Combine Echoes for Accuracy and Precision at 3 T 97%
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 98%
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 97%
- MRS-Sim: Open-Source Framework for Simulating Realistic In Vivo-like MR Spectroscopy Data 97%
Similar papers in this journal
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 98%
- Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution 98%
- Improved Statistical Efficiency of Simultaneous Multi-Slice fMRI by Reconstruction with Spatially Adaptive Temporal Smoothing 97%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.