Back

Retinal axial motion analysis and implications for real-time correction in human retinal imaging

Cai, Y.; Grieve, K.; Mece, P.

2022-01-10 bioengineering
10.1101/2022.01.07.475424 bioRxiv
Show abstract

High-resolution ophthalmic imaging devices including spectral-domain and full-field optical coherence tomography (SDOCT and FFOCT) are adversely affected by the presence of continuous involuntary retinal axial motion. Here, we thoroughly quantify and characterize retinal axial motion with both high temporal resolution (200,000 A-scans/s) and high axial resolution (4.5 {micro}m), recorded over a typical data acquisition duration of 3 s with an SDOCT device over 14 subjects. We demonstrate that although breath-holding can help decrease large-and-slow drifts, it increases small-and-fast fluctuations, which is not ideal when motion compensation is desired. Finally, by simulating the action of an axial motion stabilization control loop, we show that a loop rate of 1.2 kHz is ideal to achieve 100% robust clinical in-vivo retinal imaging.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

1
Biomedical Optics Express
84 papers in training set
Top 0.1%
44.6%
2
Journal of Biomedical Optics
25 papers in training set
Top 0.1%
9.0%
50% of probability mass above
3
Optics Letters
13 papers in training set
Top 0.1%
7.7%
4
Scientific Reports
3102 papers in training set
Top 26%
4.7%
5
Journal of Vision
92 papers in training set
Top 0.2%
3.9%
6
PLOS ONE
4510 papers in training set
Top 37%
3.9%
7
Investigative Opthalmology & Visual Science
37 papers in training set
Top 0.3%
2.2%
8
IEEE Transactions on Medical Imaging
18 papers in training set
Top 0.2%
2.2%
9
IEEE Transactions on Biomedical Engineering
38 papers in training set
Top 0.5%
1.8%
10
Translational Vision Science & Technology
35 papers in training set
Top 0.4%
1.3%
11
ACS Photonics
13 papers in training set
Top 0.3%
1.2%
12
Journal of Biophotonics
16 papers in training set
Top 0.5%
1.2%
13
Light: Science & Applications
16 papers in training set
Top 0.5%
1.0%
14
Investigative Ophthalmology & Visual Science
22 papers in training set
Top 0.2%
1.0%
15
Biophysical Journal
545 papers in training set
Top 4%
0.8%
16
Optica
25 papers in training set
Top 0.7%
0.8%
17
Neurophotonics
37 papers in training set
Top 0.5%
0.8%
18
Advanced Science
249 papers in training set
Top 17%
0.8%
19
Science Advances
1098 papers in training set
Top 32%
0.7%
20
Optics Express
23 papers in training set
Top 0.5%
0.5%
21
Journal of Neural Engineering
197 papers in training set
Top 2%
0.5%
22
Nature Communications
4913 papers in training set
Top 66%
0.5%
23
Communications Biology
886 papers in training set
Top 31%
0.5%