Multi-site Technical Performance and Concordance of Optical Genome Mapping: Constitutional Postnatal Study for SV, CNV, and Repeat Array Analysis
Iqbal, M. A.; Broeckel, U.; Levy, B.; Skinner, S.; Sahajpal, N. S.; Rodriguez, V.; Stence, A.; Awayda, K.; Scharer, G.; Skinner, C.; Stevenson, R.; Bossler, A.; Nagy, P. L.; Kolhe, R.
Show abstract
BackgroundThe standard of care (SOC) cytogenetic testing methods, such as chromosomal microarray (CMA) and Fragile-X syndrome (FXS) testing, have been employed for the detection of copy number variations (CNVs), and tandem repeat expansions/contractions that contribute towards a sizable portion of genetic abnormalities in constitutional disorders. However, CMA is unable to detect balanced structural variations (SVs) or determine the precise location or orientation of copy number gains. Karyotyping, albeit with lower resolution, has been used for the detection of balanced SVs. Other molecular methods such as PCR and Southern blotting, either simultaneously or in a tiered fashion have been used for FXS testing, adding time, cost, and complexity to reach an accurate diagnosis in affected individuals. Optical genome mapping (OGM), innovative technology in the cytogenomics arena enables a direct, high-resolution view of ultra-long DNA molecules (more than 150 kbp), which are then assembled de novo to detect germline SVs ranging from 500 bp insertions and deletions to complex chromosomal rearrangements. The purpose of this study was to evaluate the performance of OGM in comparison to the current SOC methods and assess the intra- and inter-site reproducibility of the OGM technique. We report the largest retrospective dataset to date on OGM performed at five laboratories (multi-site) to assess the robustness, QC performance, and analytical validation (multi-operator, and multi-instrument) in detecting SVs and CNVs associated with constitutional disorders compared to SOC technologies. MethodsThis multi-center IRB-approved, double-blinded, study includes a total of 331 independent flow cells run (including replicates), representing 202 unique retrospective samples, including but not limited to pediatric-onset neurodevelopmental disorders. This study included affected individuals with either a known genetic abnormality or no known genetic diagnosis. Control samples (n=42) were also included. Briefly, OGM was performed on either peripheral blood samples or cell lines using the Saphyr system. The OGM assay results were compared to the human reference genome (GRCh38) to detect different types of SVs (CNV, insertions, inversions, translocations). A unique coverage-based CNV calling algorithm was also used to complement the SV calls. Analysis of heterozygous SVs was performed to assess the absence of heterozygosity (AOH) regions in the genome. For specific clinical indications of FSHD1 and FXS, the EnFocus FXS and FSHD1 tools were used to generate the region-specific reports. OGM data was analyzed and visualized using Access software (version 1.7), where the SVs were filtered using an OGM specific internal control database. The samples were analyzed by laboratory analysts at each site in a blinded fashion using ACMG guidelines for SV interpretation and further reviewed by expert geneticists to assess concordance with SOC testing results. ResultsOf the first 331 samples run between five sites, 99.1% of sample runs were completed successfully. Of the 331 datasets, 219 were assessed for concordance by the time of this publication; these were samples that harbored known variants, of which 214/219 were detected by OGM resulting in a concordance of 97.7% compared to SOC testing. 47 samples were also run in intra- and inter-site replicate and showed 100% concordance for pathogenic CNVs and SVs and 100% concordance for pathogenic FMR1 repeat expansions. ConclusionThe results from this study demonstrate the potential of OGM as an alternative to existing SOC methods in detecting SVs of clinical significance in constitutional postnatal genetic disorders. The outstanding technical performance of OGM across multiple sites demonstrates the robustness and reproducibility of the OGM technique as a rapid cytogenomics testing tool. Notably, OGM detected all classes of SVs in a single assay, which allows for a faster result in cases with diverse and heterogeneous clinical presentations. OGM demonstrated 100% concordance for pathogenic variants previously identified including FMR1 repeat expansions (full mutation range), pathogenic D4Z4 repeat contractions (FSHD1 cases), aneuploidies, interstitial deletions, interstitial duplications, intragenic deletions, balanced translocations, and inversions. Based on our large dataset and high technical performance we recommend OGM as an alternative to the existing SOC tests for the rapid detection and diagnosis of postnatal constitutional disorders.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Clinical Validation and Diagnostic Utility of Optical Genome Mapping in Prenatal Diagnostic Testing 98%
- Concordance of whole-genome long-read sequencing with standard clinical testing for Prader-Willi and Angelman syndromes 95%
- Optical Genome Mapping: Clinical Validation and Diagnostic Utility for Enhanced Cytogenomic Analysis of Hematological Neoplasms 94%
Similar papers in this journal
- Optical genome mapping as a next-generation cytogenomic tool for detection of structural and copy number variations for prenatal genomic analyses 97%
- Evaluation of optical genome mapping in clinical genetic testing of facioscapulohumeral muscular dystrophy 95%
- Optical Genome Mapping And Single Nucleotide Polymorphism Microarray: An Integrated Approach For Investigating Challenging Cases Of Products Of Conception 94%
Similar papers in this journal
- Using single molecule Molecular Inversion Probes as a cost-effective, high-throughput sequencing approach to target all genes and loci associated with macular diseases 97%
- STRipy: a graphical application for enhanced genotyping of pathogenic short tandem repeats in sequencing data 93%
- Phasing of de novo mutations using a scaled-up multiple amplicon long-read sequencing approach 93%
Similar papers in this journal
- Evaluating Genome Sequencing Strategies: Trio, Singleton, and Standard Testing in Rare Disease Diagnosis 95%
- Genome-Wide Sequencing as a First-Tier Screening Test for Short Tandem Repeat Expansions 93%
- Recommendations for application of the functional evidence PS3/BS3 criterion using the ACMG/AMP sequence variant interpretation framework 93%
Similar papers in this journal
- Single-molecule optical mapping enables quantitative measurement of D4Z4 repeats in facioscapulohumeral muscular dystrophy (FSHD) 95%
- Exome sequencing as a first-tier test for copy number variant detection : retrospective evaluation and prospective screening in 2418 cases 95%
- A comparative medical genomics approach may facilitate the interpretation of rare missense variation 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.