Analysis of 8000 proteins and reduced carry over significantly increase the throughput of single-shot proteomics
Stejskal, K.; Op de Beeck, J.; Matzinger, M.; Duernberger, G.; Boychenko, O.; Jacobs, P.; Mechtler, K.
Show abstract
In the field of LC-MS based proteomics, increases in sampling depth and proteome coverage have mainly been accomplished by rapid advances in mass spectrometer technology. The comprehensiveness and quality of data that can be generated do however also depend on the performance provided by nano liquid chromatography (nanoLC) separations. Proper selection of reversed-phase separation columns can be important to provide the MS instrument with peptides at the highest possible concentration and separated at the highest possible resolution. In the current contribution, we evaluate the use of prototype generation 2 PAC nanoLC columns which use C18 functionalized superficially porous micro pillars as a stationary phase. When comparing to traditionally used fully porous silica stationary phases, more precursors could be characterized when performing single shot data-dependent LC-MS/MS analyses of a human cell line tryptic digest. Up to 30% more protein groups and 60% more unique peptides were identified for short gradients (10 min) and limited sample amounts (10-100 ng of cell lysate digest). With LC-MS gradient times of 10, 60, 120 and 180 min, we respectively identified 2252, 6513, 7382 and 8174 protein groups with 25, 500, 1000 and 2000 ng of sample loaded on column. Reduction of sample carry over to the next run (up to 2 to 3%) and decreased levels of methionine oxidation (up to 3-fold) were identified as additional figures of merit. When analyzing a disuccinimidyl dibutyric urea (DSBU) crosslinked synthetic library, 29 to 59 more unique crosslinked peptides could be identified at a experimentally validated false discovery rate (FDR) of 1-2%.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Ultra-sensitive nanoLC-MS of sub nanogram protein samples using second generation micro pillar array LC technology with Orbitrap Exploris 480 and FAIMS PRO 99%
- A high-sensitivity low-nanoflow LC-MS configuration for high-throughput sample-limited proteomics 98%
- Super-resolution mass spectrometry enables rapid, accurate, and highly-multiplexed proteomics at the MS2-level 98%
Similar papers in this journal
Similar papers in this journal
- A combined flow injection/reversed phase chromatography - high resolution mass spectrometry workflow for accurate absolute lipid quantification with 13C- internal standards 96%
- A rapid and universal liquid chromatograph-mass spectrometry-based platform, refmAb-Q nSMOL, for monitoring monoclonal antibody therapeutics 94%
- Profiling embryonic stem cell differentiation by MALDI TOF mass spectrometry: development of a reproducible and robust sample preparation workflow 94%
Similar papers in this journal
- SPPUSM: An MS/MS spectra merging strategy for improved low-input and single-cell proteome identification 96%
- Heterogeneous multimeric metabolite ion species observed in LC-MS based metabolomics data sets 96%
- Native Triboelectric Nanogenerator Ion Mobility-Mass Spectrometry of Egg Proteins Relevant to Objects of Cultural Heritage at Picoliter and Nanomolar Quantities. 96%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.