Back

Towards prevention of re-entrant arrhythmias: Injectable hydrogel electrodes enable direct capture of previously inaccessible cardiac tissues

Rodriguez-Rivera, G.; Post, A.; John, M.; Buchan, S.; Wancura, M.; Chwatko, M.; Waldron, C.; Kalkunte, N.; Zoldan, J.; Arseneault, M.; Razavi, M.; Cosgriff-Hernandez, E.

2021-11-04 bioengineering
10.1101/2021.11.03.467102 bioRxiv
Show abstract

Re-entrant arrhythmias--the leading cause of sudden cardiac death--are caused by diseased myocardial tissue and consequent delayed myocardial conduction. Access to the coronary veins that cross the "culprit" scar regions where re-entry originates can provide improved pacing to these delayed regions, offering a novel opportunity to prevent ventricular arrhythmias and circumvent the need for painful defibrillation, risky cardiac ablation, or toxic and often ineffective antiarrhythmic medications. However, there are no pacing electrodes which are small or focal enough to navigate these tributaries. To address this need, we have developed an injectable conductive hydrogel that can fill the epicardial coronary veins and their mid-myocardial tributaries. When connected to a standard pacing lead, these injected hydrogels can be converted into flexible electrodes that directly pace the previously inaccessible mid-myocardial tissue. In our two-component system, hydrogel precursor solutions can be injected through a dual lumen catheter in a minimally invasive deployment strategy to provide direct access to the diseased regions with precision and ease. Mixing of the two solutions upon injection into the vein activates redox-initiated crosslinking of the gel for rapid in situ cure without an external stimulus. An ex vivo porcine model was used to identify the requisite viscosity and cure rate for gel retention and homogeneity. Ionic species added to the hydrogel precursor solutions conferred conductivity above target myocardium values that was retained after implantation. Successful in vivo deployment demonstrated that the hydrogel electrode filled the anterior interventricular vein with extension into the septal (mid-myocardial) venous tributaries to depths far more distal and refined than any current technologies allow. In addition to successful capture and pacing of the heart, analysis of surface ECG tracings revealed a novel pacing observation highly specific for and suggestive of capture of extensive swaths of septal myocardial tissue. This is the first report of an injectable electrode used to successfully pace the mid-myocardium and mimic physiologic conduction. Furthermore, in vivo cardiac electroanatomical mapping studies in an ablation scar model showed uniform capture along the hydrogel in the vessels as well as increased capture area compared to point pacing. Collectively, these findings demonstrate that this injectable hydrogel electrode can be deployed to scarred regions of the heart to provide a reliable pacing modality that most closely resembles native conduction with the potential to eliminate delayed myocardial conduction and associated re-entry. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=179 SRC="FIGDIR/small/467102v2_ufig1.gif" ALT="Figure 1"> View larger version (50K): org.highwire.dtl.DTLVardef@1577526org.highwire.dtl.DTLVardef@cc510dorg.highwire.dtl.DTLVardef@1dd426eorg.highwire.dtl.DTLVardef@1346aab_HPS_FORMAT_FIGEXP M_FIG C_FIG One Sentence SummaryInjectable hydrogel electrodes achieve pacing that mimics physiologic conduction by capturing midmyocardial tissue

Matching journals

The top 6 journals account for 50% of the predicted probability mass.

1
ACS Biomaterials Science & Engineering
37 papers in training set
Top 0.1%
18.2%
2
Advanced Healthcare Materials
85 papers in training set
Top 0.1%
12.7%
3
Advanced Functional Materials
46 papers in training set
Top 0.1%
7.2%
4
Advanced Science
286 papers in training set
Top 1%
5.1%
5
Biomaterials
84 papers in training set
Top 0.3%
5.1%
6
Advanced Materials
56 papers in training set
Top 0.3%
4.0%
50% of probability mass above
7
Journal of Biomedical Materials Research Part A
20 papers in training set
Top 0.1%
3.4%
8
Advanced Materials Technologies
29 papers in training set
Top 0.2%
3.4%
9
Bioengineering & Translational Medicine
21 papers in training set
Top 0.1%
3.2%
10
Acta Biomaterialia
92 papers in training set
Top 0.5%
3.2%
11
Biomaterials Science
24 papers in training set
Top 0.2%
3.1%
12
Biofabrication
36 papers in training set
Top 0.3%
2.6%
13
Lab on a Chip
96 papers in training set
Top 0.5%
2.1%
14
Biomacromolecules
29 papers in training set
Top 0.2%
2.1%
15
Materials Today Bio
20 papers in training set
Top 0.3%
2.1%
16
Small
78 papers in training set
Top 0.7%
2.1%
17
Bioactive Materials
20 papers in training set
Top 0.3%
1.7%
18
Science Advances
1243 papers in training set
Top 23%
1.3%
19
Advanced Therapeutics
17 papers in training set
Top 0.2%
1.1%
20
PLOS ONE
5266 papers in training set
Top 57%
1.0%
21
Journal of Controlled Release
44 papers in training set
Top 0.7%
1.0%
22
ACS Applied Materials & Interfaces
39 papers in training set
Top 0.8%
1.0%
23
Annals of Biomedical Engineering
37 papers in training set
Top 1%
0.8%
24
Nature Biomedical Engineering
47 papers in training set
Top 2%
0.6%
25
Nature Communications
5641 papers in training set
Top 60%
0.6%