Parameter Sensitivity and Experimental Validation for Fractional-Order Dynamical Modeling of Neurovascular Coupling
Belkhatir, Z.; Alhazmi, F.; Bahloul, M.; Laleg-Kirati, T.-M.
Show abstract
GoalNeurovascular coupling is a fundamental mechanism linking neural activity to cerebral blood flow (CBF) response. Modeling this coupling is very important to understand brain functions, yet challenging due to the complexity of the involved phenomena. One key feature that different studies have reported is the time delay that is inherently present between the neural activity and cerebral blood flow, which has been described by adding a delay parameter in standard models. An alternative approach was recently proposed where the framework of fractional-order modeling is employed to characterize the complex phenomena underlying the neurovascular. Thanks to its nonlocal property, a fractional derivative is suitable for modeling delayed and power-law phenomena. MethodsIn this study, we analyzed and validated an effective fractional-order for the effective modeling and characterization of the neurovascular coupling mechanism. To show the added value of the fractional order parameters of the proposed model, we perform a parameter sensitivity analysis of the fractional model compared to its integer counterpart. Moreover, the model was validated using neural activity-CBF data related to both event and block design experiments that were acquired using electrophysiology and laser Doppler flowmetry recordings, respectively. ResultsThe validation results show the aptitude and flexibility of the fractional-order paradigm in fitting a more comprehensive range of well-shaped CBF response behaviors while maintaining a low model complexity. Comparison with the standard integer-order models shows the added value of the fractional-order parameters in capturing various key determinants of the cerebral hemodynamic response, e.g., post-stimulus undershoot. ConclusionsThis investigation authenticates the ability and adaptability of the fractional-order framework to characterize a wider range of well-shaped cerebral blood flow responses while preserving low model complexity through a series of unconstrained and constrained optimizations. Impact StatementThe present study proposes a novel fractional-order framework for modeling neurovascular coupling. A parameter sensitivity analysis demonstrates the potential flexibility, and effectiveness of the fractional-order paradigm in reconstructing the cerebral hemodynamics with manageable complexity; and a real experimental validation analysis demonstrates the ability of the model in modeling a wider range of well-shaped CBF responses.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Identifiability analysis and noninvasive online estimation of the first-order neural activation dynamics in the brain with closed-loop transcranial magnetic stimulation 97%
- Surgical Planning and Optimization of Patient-Specific Fontan Grafts With Uncertain Post-Operative Boundary Conditions and Anastomosis Displacement 95%
- Personalizing the Pressure Reactivity Index for Neurocritical Care Decision Support 94%
Similar papers in this journal
- Comparing physiological impacts of positive pressure ventilation versus self-breathing via a versatile cardiopulmonary model incorporating a novel alveoli opening mechanism 94%
- Personalized computational hemodynamic analysis in transcatheter aortic valve: investigation of long-term degeneration 93%
- Optimization-Based Synthesis with Directed Cell Migration 93%
Similar papers in this journal
- Structural and practical identifiability of contrast transport models for DCE-MRI 96%
- Uncertainty quantification in cerebral circulation simulations focusing on the collateral flow: Surrogate model approach with machine learning 95%
- Convergence, Sampling And Total Order Estimator Effects On Parameter Orthogonality In Global Sensitivity Analysis 95%
Similar papers in this journal
- Fluid-structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements 93%
- Mesh-Free High-Resolution Simulation Of Cerebrocortical Oxygensupply With Fast Fourier Preconditioning 93%
- ATP diffusional gradients are sufficient to maintain bioenergetic homeostasis in synaptic boutons lacking mitochondria 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.