Thermal Camera detection of High Temperature for mass COVID Screening
Maguire, R. S.; Hogg, M.; Carrie, I. D.; Blaney, M.; Couturier, A.; Longbottom, L.; Thomson, J.; Thompson, A.; Warren, C.; Lowe, D. J.
Show abstract
The COVID-19 [SARS-COV-2] pandemic has had a devastating global impact, with both the human and socio economic costs being severe. One result of the COVID-19 pandemic is the emergence of an urgent requirement for effective techniques and technologies for screening individuals showing symptoms of infection in a non-invasive and non-contact way. Systems that exploit thermal imaging technology to screen individuals show promise to satisfy the desired criteria, including offering a non-contact, non-invasive method of temperature measurement. Furthermore, the potential for mass and passive screening makes thermal imaging systems an attractive technology where current standard of care methods are not practical. Critically, any fever screening solution must be capable of accurate temperature measurement and subsequent prediction of core temperature. This is essential to ensure a high sensitivity in identifying fever while maintaining a low rate of false positives. This paper discusses the results and analysis of a clinical trial undertaken by Thales UK Ltd and the Queen Elizabeth University Teaching Hospital in Glasgow to assess the accuracy and operation of the High Temperature Detection (HTD) system developed by Thales UK Ltd when used in a clinical setting. Results of this single centre prospective observational cohort study show that the measured laboratory accuracy of the Thales HTD system (RMSE=0.1{degrees}C) is comparable to the accuracy when used in a clinical setting (RMSE = 0.15{degrees}C) when measuring a calibrated blackbody source at typical skin temperature. For measurement of forehead skin temperature, the system produced results commensurate with close contact measurement methods (R = 0.86, Mean error=0.05{degrees}C).. Compared to measured tympanic temperatures, measurement of the forehead skin temperature by the HTD system showed a moderate correlation (R = 0.43),), which is stronger than close contact IR forehead thermometers (R = 0.20,0.35) An improved correlation was observed between the maximum facial temperature measured by the HTD system and measured tympanic temperatures (R = 0.53), which is significantly stronger than the close contact methods. A linear predictive model for tympanic temperature based on the measured maximum facial temperatures resulted in a root mean square error (RMSE = 0.50{degrees}C) that is marginally larger than what is expected as a compound of errors in the measuring devices (RMSE=0.45{degrees}C). The study demonstrates that the HTD could be applied in the clinical and non-clinical setting as a screening mechanism to detect citizens with raised temperature. This approach would enable high volume surveillance and identification of individuals that contribute to further spread of COVID-19. Deployment of the HTD system could be implemented as part of a screening tool to support measures to enhance public safety and confidence in areas of high throughput, such as airports, shopping centres or places of work.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A low-cost protocol for reconditioning of deep-brain neural microelectrodes with material failure for electrophysiology recording 90%
- Model for Deformation of Cells from External Electric Fields at or Near Resonant Frequencies 89%
- SimBSI: An open-source Simulink library for developingclosed-loop brain signal interfaces in animals and humans 89%
Similar papers in this journal
- What is the value of community oximetry monitoring in people with SARS-CoV-2? – A prospective, open-label clinical study 89%
- AI-based image quality assessment in CT 88%
- Adverse events following COVID-19 virus vaccination in Japanese young population: The first cross-sectional study conducted by a questionnaire survey after the first-time-injection 88%
Similar papers in this journal
- A Cross-sectional Feasibility Study to Evaluate the Usability and Efficacy of “Swaasa”: An AI-Platform for Rapid Respiratory Health Assessment 92%
- Development and Clinical Validation of Swaasa AI Platform for screening and prioritization of Pulmonary TB 92%
- Ambulatory physiological measures obtained under naturalistic urban mobility conditions have acceptable reliability 91%
Similar papers in this journal
- Measuring Repositioning in Home Care for Pressure Injury Prevention and Management 94%
- A computational study on the role of parameters for identification of thyroid nodules by infrared images (and its comparison with real data) 94%
- Combining Indoor Positioning Using Wi-Fi Round-trip Time with Dust Measurement in the Field of Occupational Health 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.