A comparison of denoising methods in dynamic MRS using pseudo-synthetic data
Rowland, B. C.; Sreepada, L.; Lin, A. P.
Show abstract
PurposeMR spectroscopy of dynamic systems is limited by low signal to noise. Denoising along a series of acquired spectra exploits their temporal correlation to improve the quality of individual spectra, and reduce errors in fitting metabolite peaks. In this study we compare the performance of several denoising methods. MethodsSix different denoising methods were considered: SIFT (Spectral Improvement by Fourier Thresholding), HSVD (Hankel Singular Value Decomposition), spline, wavelet, sliding window and sliding Gaussian. Pseudo-synthetic data was constructed to mimic 31Phosphorus spectra from exercising muscle. For each method the optimal tuning parameters were determined for SNRs of 2, 5, 10 and 20 using a Monte Carlo approach. Denoised data from each method was then fitted using the AMARES algorithm and the results compared to the pseudo-synthetic ground truth. ResultsAll six methods produced improvements in both fitting accuracy and agreement with the ground truth, compared to unprocessed noisy data. The least effective methods, SIFT and HSVD, achieved around 10-20% reduction in RMS error, while the most effective, Spline, reduced RMS error by 70%. The improvement from denoising was typically greater for lower SNR data. ConclusionsIndirect time domain denoising of dynamic MR spectroscopy data can substantially improve subsequent metabolite fitting. Spline-based denoising was found to be the most flexible and effective technique.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Meta-analysis and Open-source Database for In Vivo Brain Magnetic Resonance Spectroscopy Studies of Health and Disease 92%
- A Comprehensive Guide to MEGA-PRESS for GABA Measurement 90%
- Parameter estimation and identifiability analysis for a bivalent analyte model of monoclonal antibody-antigen binding 87%
Similar papers in this journal
- MRS-Sim: Open-Source Framework for Simulating Realistic In Vivo-like MR Spectroscopy Data 95%
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 94%
- Improving reproducibility of proton MRS brain thermometry: theoretical and empirical approaches 93%
Similar papers in this journal
- Magnetic Resonance Spectroscopy Spectral Registration Using Deep Learning 96%
- Improved characterization of diffusion in normal and cancerous prostate tissue through optimization of the restriction spectrum imaging signal model 92%
- Correction of Artifacts Induced by B0 Inhomogeneities in Breast MRI using Reduced Field-of-View Echo-Planar Imaging and Enhanced Reverse Polarity Gradient Method 92%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.