Accuracy of Smartphone Integrated Pulse Oximetry Meets Full FDA Clearance Standards for Clinical Use.
Browne, S. H.; Bernstein, M.; Bickler, P. E.
Show abstract
BackgroundPulse oximetry is used as an assessment tool to gauge the severity of COVID-19 infection and identify patients at risk of poor outcomes. 1,2,3,4 The pandemic highlights the need for accurate pulse oximetry, particularly at home, as infection rates increase in multiple global regions including the UK, USA and South Africa 5. Over 100 million Samsung smartphones containing dedicated biosensors (Maxim Integrated Inc, San Jose, CA) and preloaded Apps to perform pulse oximetry, are in use globally. We performed detailed in human hypoxia testing on the Samsung S9 smartphone to determine if this integrated hardware meets full FDA/ISO requirements for clinical pulse oximetry. MethodsThe accuracy of integrated pulse oximetry in the Samsung 9 smartphone during stable arterial oxygen saturations (SaO2) between 70% and 100% was evaluated in 12 healthy subjects. Inspired oxygen, nitrogen, and carbon dioxide partial pressures were monitored and adjusted via a partial rebreathing circuit to achieve stable target SaO2 plateaus between 70% and 100%. Arterial blood samples were taken at each plateau and saturation measured on each blood sample using ABL-90FLEX blood gas analyzer. Bias, calculated from smartphone readings minus the corresponding arterial blood sample, was reported as root mean square deviation (RMSD). FindingsThe RMSD of the over 257 data points based on blood sample analysis obtained from 12 human volunteers tested was 2.6%. InterpretationEvaluation of the smartphone pulse oximeter performance is within requirements of <3.5% RMSD blood oxygen saturation (SpO2) value for FDA/ISO clearance for clinical pulse oximetry. This is the first report of smartphone derived pulse oximetry measurements that meet full FDA/ISO accuracy certification requirements. Both Samsung S9 and S10 contain the same integrated pulse oximeter, thus over 100 million smartphones in current global circulation could be used to obtain clinically accurate spot SpO2 measurements to support at home assessment of COVID-19 patients.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Diagnosing Chronic Obstructive Airway Disease: a diagnostic accuracy study of a smartphone delivered algorithm combining patient-reported symptoms and cough analysis for use in acute care consultations. 90%
- Remote patient monitoring and digital therapeutics in heart failure: lessons from the Continuum pilot study 90%
- Improving emergency department patient-doctor conversation through an artificial intelligence symptom taking tool: an action-oriented design pilot study 89%
Similar papers in this journal
- Assessing the Safety of Home Oximetry for Covid-19: A multi-site retrospective observational study 93%
- HEART rate variability biofeedback for LOng Covid symptoms (HEARTLOC): protocol for a feasibility study 91%
- The Diagnostic Accuracy of Subjective Dyspnea in Detecting Hypoxemia Among Outpatients with COVID-19 91%
Similar papers in this journal
- Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients 96%
- Remote-management of COPD: Evaluating Implementation of Digital Innovation to Enable Routine Care (RECEIVER) – Protocol for a feasibility and service adoption observational cohort study 90%
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 89%
Similar papers in this journal
- Smartphone screening for neonatal jaundice via ambient-subtracted sclera chromaticity: neoSCB app pilot study 93%
- Validity and reliability of an app-based medical device to empower individuals in evaluating their physical capacities 92%
- Impact of Skin Tone, Environmental, and Technical Factors on Thermal Imaging 91%
Similar papers in this journal
- Automated Image Transcription for Perinatal Blood Pressure Monitoring Using Mobile Health Technology 92%
- The High Price of Equity in Pulse Oximetry: A cost evaluation and need for interim solutions 92%
- Feasibility characteristics of wrist-worn fitness trackers in health status monitoring for post-COVID patients in remote and rural areas 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.