Focused X-ray Luminescence Computed Tomography using a Continuous Scanning Scheme
Lun, M. C.; Fang, Y.; Li, C.
Show abstract
X-ray luminescence computed tomography (XLCT) imaging is a hybrid molecular imaging modality combining the merits of both conventional x-ray imaging (high spatial resolution) and optical imaging (high measurement sensitivity). The narrow x-ray beam based XLCT imaging has been shown to be promising. However due to the selective excitation scheme, the imaging speed is slow thus limiting its practical applications for in vivo imaging. In this work, we have introduced a continuous scanning scheme to acquire data for each angular projection in one motion, eliminating the previous stepping scheme and reducing the data acquisition time, which makes it feasible for multiple transverse scans for three-dimensional (3D) imaging. We have introduced a high accuracy vertical stage to our focused x-ray beam based XLCT imaging system to perform high-resolution and 3D XLCT imaging. We have also included a scintillator crystal coupled to a PMT to act as a single-pixel detector for boundary detection purposes to replace our previous flat panel x-ray detector. We have verified the feasibility of our proposed scanning scheme and imaging system by performing phantom experimental studies. A phantom was embedded with a set of cylindrical targets with 200 {micro}m edge-to-edge distance and was scanned in our imaging system with the proposed method. To test the feasibility for 3D scanning, we took measurements from 4 transverse slices with a vertical step size of 1 mm. The results of the experiments verified the feasibility of our proposed method to perform 3D XLCT imaging using a narrow x-ray beam in a reasonable time.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- High precision fluorescence tomography-guided system for pre-clinical radiation research: system design and validation 97%
- Contrast-enhanced photon-counting micro-CT of tumor xenograft models 95%
- Development of a Coupled Simulation Toolkit for Computational Radiation Biology Based on Geant4 and CompuCell3D 95%
Similar papers in this journal
- A metal artifact reduction method for small field of view CT imaging. 96%
- Inclusion of a GaAs detector model in the Photon Counting Toolkit software for the study of breast imaging systems 96%
- Single-cell radioluminescence microscopy with two-fold higher sensitivity using dual scintillator configuration 95%
Similar papers in this journal
- Unsupervised determination of lung tumor margin with widefield polarimetric second-harmonic generation microscopy 93%
- Dependence of fluorodeoxyglucose (FDG) uptake on cell cycle and dry mass: a single-cell study using a multi-modal radiography platform 93%
- The optics of the human eye at 8.6 µm lateral resolution 92%
Similar papers in this journal
- An evaluation of resonant scanning as a high-speed imaging technique for two-photon imaging of cortical vasculature 95%
- Non-Degenerate Two-Photon Imaging of Deep Rodent Cortex using Indocyanine Green in the water absorption window 95%
- A scalable, multi-wavelength, broad bandwidth frequency-domain near-infrared spectroscopy platform for real-time quantitative tissue optical imaging 94%
Similar papers in this journal
- CellSNAP: A fast, accurate algorithm for 3D cell segmentation in quantitative phase imaging 95%
- Segmentation of the Urothelium in Optical Coherence Tomography Images with Dynamic Contrast 94%
- Application of Transfer Learning for Rapid Calibration of Spatially-resolved Diffuse Reflectance Probes for Extraction of Tissue Optical Properties 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.