The sensitivity of ECG contamination to surgical implantation site in adaptive closed-loop neurostimulation systems
Neumann, W.-J.; Memarian Sorkhabi, M.; Benjaber, M.; Feldmann, L. K.; Saryyeva, A.; Krauss, J. K.; Sieger, T.; Jech, R.; Contarino, M. F.; Tinkhauser, G.; Pollo, C.; Palmisano, C.; Isaias, I. U.; Cummins, D.; Little, S. J.; Starr, P. A.; Kokkinos, V.; Schneider, G.-H.; Herrington, T.; Brown, P.; Richardson, R. M.; Kuehn, A. A.; Denison, T.
Show abstract
BackgroundBrain sensing devices are approved today for Parkinsons, essential tremor, and epilepsy therapies. Clinical decisions for implants are often influenced by the premise that patients will benefit from using sensing technology. However, artifacts, such as ECG contamination, can render such treatments unreliable. Therefore, clinicians need to understand how surgical decisions may affect artifact probability. ObjectivesInvestigate neural signal contamination with ECG activity in sensing enabled neurostimulation systems, and in particular clinical choices such as implant location that impact signal fidelity. MethodsElectric field modelling and empirical signals from 85 patients were used to investigate the relationship between implant location and ECG contamination.a ResultsThe impact on neural recordings depends on the difference between ECG signal and noise floor of the electrophysiological recording. Empirically, we demonstrate that severe ECG contamination was more than 3.2x higher in left-sided subclavicular implants (48.3%), when compared to right-sided implants (15.3%). Cranial implants did not show ECG contamination. ConclusionsGiven the relative frequency of corrupted neural signals, we conclude that implant location will impact the ability of brain sensing devices to be used for "closed-loop" algorithms. Clinical adjustments such as implant location can significantly affect signal integrity and need consideration. HighlightsO_LIChronic embedded brain sensing promises algorithm-based neurostimulation C_LIO_LIAlgorithms for closed-loop stimulation can be impaired by artifacts C_LIO_LIThe relationship of implant location to cardiac dipole has relevant impact on neural signal fidelity; simple models can provide guidance on the sensitivity C_LIO_LIECG artifacts are present in up to 50% of neural signals from left subclavicular DBS systems C_LIO_LIImplanting DBS in a right subclavicular location significantly reduces frequency of ECG artifacts C_LIO_LICranial-mounted implants are relatively immune to artifacts C_LI
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Automated optimization of deep brain stimulation parameters for modulating neuroimaging-based targets 95%
- Computational modeling of dorsal root ganglion stimulation using an Injectrode 94%
- Long-Term Performance of Utah Slanted Electrode Arrays and Intramuscular Electromyographic Leads Implanted Chronically in Human Arm Nerves and Muscles 94%
Similar papers in this journal
- Automated artifact injection into sensing-capable brain modulation devices for neural-behavioral synchronization and the influence of device state 96%
- Controlling pallidal oscillations in real-time in Parkinson's disease using evoked interference deep brain stimulation (eiDBS): proof of concept in the human 95%
- Adaptive current-flow models of ECT: Explaining individual static impedance, dynamic impedance, and brain current delivery 95%
Similar papers in this journal
- Endogenous signals during active movement predict deep brain stimulation evoked potential pathways: Results of a transfer function analysis 95%
- Optimal Multichannel Artifact Prediction and Removal for Brain Machine Interfaces and Neural Prosthetics 93%
- Simulation of closed-loop deep brain stimulation control schemes for suppression of pathological beta oscillations in Parkinson's disease 92%
Similar papers in this journal
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? 95%
- Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T 94%
- Intracranial approach for sub-second monitoring of neurotransmitters during DBS electrode implantation does not increase infection rate 93%
Similar papers in this journal
- Probabilistic comparison of gray and white matter coverage between depth and surface intracranial electrodes in epilepsy: a patient-specific modeling and empirical study 94%
- EEG-based diagnostics of the auditory system using cochlear implant electrodes as sensors 94%
- Group and Individual Level Variations between Symmetric and Asymmetric DLPFC Montages for tDCS over Large Scale Brain Network Nodes 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.