PolyJet 3D Printing of Tissue Mimicking Materials: An Investigation of Characteristic Properties of 3D Printed Synthetic Tissue
Lee, V.; Severseike, L.; Bakken, C.; Bermel, E.; Bhatia, V.
Show abstract
Current anatomical 3D printing has been primarily used for education, training, and surgical planning purposes. This is largely due to the models being printed in materials which excel at replicating macro-level organic geometries; however, these materials have the drawback of unrealistic mechanical behavior and system properties compared to biological tissue. The new Digital Anatomy (DA) family of materials from Stratasys utilizes composite printed materials to more closely mimic mechanical behavior of biological tissue, potentially allowing more realistic models for design evaluation. Various experimental DA Solid Organ (SO) configurations were quantitatively evaluated under axial loading for comparison with porcine liver in terms of stiffness. Additionally, Structural Heart - Myocardium (Myo) configurations were quantitatively evaluated under different lubricant conditions for comparison with porcine epicardium and aorta in terms of lubricity. Finally, experimental DA Subcutaneous Tissue configurations were qualitatively evaluated by experts with significant pre-clinical implant experience for cutting, tunneling, and puncture procedures. In general, the experimental SO configurations showed promising compliance results when compared to porcine liver. The stiffness of DA configurations was either within the same range or on the lower bound of porcine tissue stiffness values. The lubricity of DA configurations with surface treatments was comparable with porcine epicardium and aorta. In terms of qualitative cutting, DA did not perform well for any of the configurations; however, tunneling and puncture were rated favorably for some of the experimental configurations. Despite some limitations, DA feels closer to real tissue than other commercially available 3D printed materials. Furthermore, the lower sample-to-sample variability of DA allows for repeatability not provided by biological tissue. The promising results and repeatability indicate that DA materials can be used to configure structures with similar characteristic mechanical properties to porcine liver, epicardium, and subcutaneous tissue, adding new value as not only an educational, training, and surgical tool, but also as a research tool.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- An Investigation into Patient-Specific 3D Printed Titanium Stents and the use of Etching to Overcome Selective Laser Melting Design Constraints. 96%
- Nonthermal plasma treatment of polymers modulates biological fouling but can cause material embrittlement 95%
- A Plantar Surface Shear Strain Methodology Utilising Digital Image Correlation 94%
Similar papers in this journal
- Collagen fibre-mediated mechanical damage increases calcification of bovine pericardium for use in bioprosthetic heart valves 95%
- Equilibrium Tension and Compression Mechanical Properties of the Human Uterus 95%
- Generative design approach to combine architected Voronoi foams with porous collagen scaffolds to create a tunable composite biomaterial 94%
Similar papers in this journal
- Urological benchtop and in silico models validated by human penile tissue inflation tests 96%
- Precision in Spinal Cord Injury Research: A Novel Electromagnetic Impactor for a Consistent Porcine Model 94%
- Fully Implanted Prostheses for Musculoskeletal Limb Reconstruction after Amputation: An In Vivo Feasibility Study 93%
Similar papers in this journal
- Sensor Fusion Algorithm to Improve Accuracy of Robotic Superposition Testing using 6-DOF Position Sensors 92%
- Comparison of two different finite element modeling pipelines for virtual mechanical testing of the distal third metacarpal bone in Thoroughbred racehorses 91%
- Acute repair of meniscus root tear partially restores joint displacements as measured with MRI and loading in a porcine knee 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.