Aerosols created by dental procedures in a primary care setting
Hobson, R. S.; Pabary, S. B.; Amlani, K.; Badminton, K.
Show abstract
The study was undertaken to record the amount of dental aerosol created using 3-in-1 syringe, air rotor, and ultrasonic scaler using high volume suction (HVS) in 5 primary care dental surgeries. The time for the aerosol to dissipate following completion of the procedure was also recorded. The amount of aerosol created above the background level for the surgery corresponding to the operating positions of the nurse, dentist, and patient was recorded using particle meters measuring the number of 2.5{micro}m (PM2.5) and 10{micro}m (PM10) particles respectively. The procedures were recorded in triplicate for each surgery and average change calculated for each procedure, lasting 90 seconds. PM2.5 remained at or very near background readings during all procedures, whereas PM10 increased with use of the air rotor and to a much lower extent with both 3-in-1, and ultrasonic scaler. The means time to return to background reading level was 2.5 minutes. It was concluded that PM2.5 levels did not rise and although PM10 increased for all procedures the increase was low and with a return to background readings within 2m:50s (95% CI: 2:34 to 3:37) of completing the procedures that a minimum fallow period of 5minutes would allow be more than ample to be safe.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Evaluation of silver nanoparticles for the prevention of SARS-CoV-2 infection in health workers: in vitro and in vivo 94%
- N95 respirators, disposable procedure masks and reusable cloth face coverings: total inward leakage and filtration efficiency of materials against aerosol 94%
- Sterilization of disposable face masks with respect to COVID-19 shortages; a nationwide field study including 19 sterilisation departments 93%
Similar papers in this journal
- A Comparison of Aerosol Mitigation Strategies and Aerosol Persistence in Dental Environments 97%
- Disinfection effect of pulsed xenon ultraviolet irradiation on SARS-CoV-2 and implications for environmental risk of COVID-19 transmission 90%
- Scalable In-hospital Decontamination of N95 Filtering Facepiece Respirator with a Peracetic Acid Room Disinfection System 90%
Similar papers in this journal
- Experimental efficacy of the face shield and the mask against emitted and potentially received particles 95%
- The impact of large mobile air purifiers on aerosol concentration in classrooms and the reduction of airborne transmission of SARS-CoV-2 92%
- Gastroenterology Procedures Generate Aerosols: an Air Quality Turnover Solution to Mitigate the Risk 92%
Similar papers in this journal
- Scalable, effective, and rapid decontamination of SARS-CoV-2 contaminated N95 respirators using germicidal ultra-violet C (UVC) irradiation device 92%
- Lack of pulmonary fibrogenicity and carcinogenicity of titanium dioxide nanoparticles in 26-week inhalation study in rasH2 mouse model 92%
- The virucidal effects of 405 nm visible light on SARS-CoV-2 and influenza A virus 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.