Heat-based Decontamination of N95 Masks Using a Commercial Laundry Dryer
Lensky, Y. D.; Mazenc, E.; Ranard, D.; Vilim, M.; Prakash, M.; Brooks, B.; Bradley, A.; Engelschenschilt, A.; Plutz, J.; Zellmer, T.
Show abstract
We propose a dry heat method for decontaminating N95 masks of SARS-CoV-2, designed around placing them in resealable plastic bags, packed in large cardboard boxes installed at the rear end of commercial laundry dryers. Our protocol rests on data collected in collaboration with Alliance Laundry Systems (ALS) and the CDC/NIOSH laboratories, under the "NPPTL Respirator Assessments to Support the COVID-19 Response" initiative. We test the two most widely available ALS tumbler models, the UTF75N and UT075N, and show that if our procedure is carefully followed, the masks will be subject to suitably high and stable temperatures for decontamination; in particular the masks will be heated to at least 80 {degrees}C for at least 65 min. For the mask models 3M 1860, 3M 8511, and Halyard 62126, we establish that they pass quantitative fit tests and retain sufficient filtration performance after three cycles of our decontamination procedure. All masks used in this study were new and uncontaminated: the evidence for the levels of biological inactivation of SARS-CoV-2 is provided by [1]. While the protocol outlined here is currently specific to certain tested dryer models, this equipment is widely available, with machines estimated to be within 15 minutes of most US hospitals. Models from other manufacturers may also be appropriate for this decontamination method, though we stress the need for explicit testing on alternative models before use.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- N95 respirators, disposable procedure masks and reusable cloth face coverings: total inward leakage and filtration efficiency of materials against aerosol 95%
- The new silicone N99 half-piece respirator, VJR-NMU N99: A novel and effective tool to prevent COVID-19 95%
- Decontamination of Geobacillus Stearothermophilus Using the Arca Aerosolized Hydrogen Peroxide Decontamination System 95%
Similar papers in this journal
- Handling and Packaging of Medical Bags at the Acute Disaster Site Under High Temperature Conditions 89%
- Effect of Heat inactivation and bulk lysis on Real-Time Reverse Transcription PCR Detection of the SARS-COV-2: An Experimental Study 88%
- Occupational safety and health aspects of corporate social responsibility reporting in Japan: comparison between 2012 and 2020 86%
Similar papers in this journal
- Assessment of Environmental and Occupational Risk Factors for the Mitigation and Containment of a COVID-19 Outbreak in a Meat Processing Plant 90%
- Providing a safe, in-person, residential college experience during the COVID-19 pandemic 89%
- Aerosol Formation During Processing of Potentially Infectious Samples on Roche Immunochemistry Analyzers (cobas e analyzers) and in an End-to-End Laboratory Workflow to Model SARS-CoV-2 Infection Risk for Laboratory Operators 89%
Similar papers in this journal
- Computational Fluid Dynamics Modeling of Cough Transport in an Aircraft Cabin 95%
- Evaluation of Different Types of Face Masks to Limit the Spread of SARS-CoV-2 – A Modeling Study 94%
- Scalable, effective, and rapid decontamination of SARS-CoV-2 contaminated N95 respirators using germicidal ultra-violet C (UVC) irradiation device 92%
Similar papers in this journal
- Extended use or re-use of single-use surgical masks and filtering facepiece respirators: A rapid evidence review 92%
- A Comparison of Aerosol Mitigation Strategies and Aerosol Persistence in Dental Environments 90%
- Scalable In-hospital Decontamination of N95 Filtering Facepiece Respirator with a Peracetic Acid Room Disinfection System 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.