Magnetic Temporal Interference For Noninvasive, High-resolution, and Localized Deep Brain Stimulation: Concept Validation
Zaeimbashi, M.; Khalifa, A.; Dong, C.; Wei, Y.; Cash, S.; Sun, N.
Show abstract
Non-invasive deep brain stimulation has been a major challenge in the field of neuroscience and brain stimulation in the past three decades. Current brain stimulation technologies suffer from such hurdles as the inability to do deep brain stimulation, poor spatial resolution, and invasiveness. Transcranial magnetic stimulation (TMS) technique, for instance, cannot target brain regions deeper than [~]2cm and has a poor spatial resolution, impacting a large area of the peripheral region and leading to various side effects. Implantable electrodes, even though effective for deep brain stimulation, are invasive and carry various drawbacks related to the surgery and site infection. In this paper, we propose a new concept that relies on temporal interference of two high- frequency magnetic fields generated by two electromagnetic coils. The neural system does not respond to each of these high-frequency magnetic fields alone because of the intrinsic low-pass filtering properties of the neural membrane. The peripheral areas of the brain are impacted only by the high-frequency magnetic fields that cannot stimulate the nerves, while the deep brain area where the two fields interfere experiences a magnetic field that contains a low-frequency envelope and therefore the nerves can be stimulated. This technique can noninvasively focus a magnetic or electric beam at any depth inside the brain with a high resolution, without impacting the peripheral regions.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Magnetic Temporal Interference for Noninvasive Focal Brain Stimulation 97%
- Non-invasive stimulation with Temporal Interference: Optimization of the electric field deep in the brain with the use of a genetic algorithm 96%
- Measuring Transcranial Magnetic Stimulation-Induced Electric Fields in Anatomically and Conductively Accurate Rat Head Phantoms 95%
Similar papers in this journal
- Bio-Physical Modeling of Galvanic Human Body Communication in Electro-Quasistatic Regime 93%
- Advanced Biophysical Model to Capture Channel Variability for EQS Capacitive HBC 93%
- Identifiability analysis and noninvasive online estimation of the first-order neural activation dynamics in the brain with closed-loop transcranial magnetic stimulation 93%
Similar papers in this journal
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? 94%
- Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants 94%
- Rattractor - Instant guidance of a rat into a virtual cage using a deep brain stimulation 93%
Similar papers in this journal
- Biophysical modeling of the electric field magnitude and distribution induced by electrical stimulation with intracerebral electrodes 94%
- A low-cost protocol for reconditioning of deep-brain neural microelectrodes with material failure for electrophysiology recording 92%
- SimBSI: An open-source Simulink library for developingclosed-loop brain signal interfaces in animals and humans 91%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.