Application of Surgical Lead Management and Reconfigurable Coil Technology to Reduce RF Heating of DBS Implants during MRI at 3T Under Variant Body Compositions
Bhusal, B.; Elahi, B.; Keil, B.; Rosenow, J.; Kazemivalipour, E.; Golestani Rad, L.
Show abstract
Patients with active implants such as deep brain stimulation (DBS) devices, have limited access to magnetic resonance imaging (MRI) due to risks of RF heating. With an aging population, the prevalence of neurodegenerative and vascular disease increases; and so does the indication for MRI exams in patients with such implants. In response to this growing need for MRI, many groups have investigated strategies to mitigate the RF heating of the implants. These efforts, however, have relied either on simulations with homogenous body models or simplified phantom experiments (box shaped phantom with single tissue). It is well established, however, that the shape and heterogeneity of human body affects the distribution of MRI electric fields, which by proxy, alters the RF heating of an implant inside the body. In this contribution, we applied numerical simulations and phantom experiments to examine the effectiveness of RF heating mitigation strategies under variant patient body compositions, focusing on two recently proposed techniques: (a) surgical modification of DBS lead trajectories inside the body, and (b) use of a patient-adjustable reconfigurable MRI coil, both aiming to reduce the coupling of implanted leads and MRI electric fields. Our results demonstrated that both techniques perform well under variant body compositions.Competing Interest StatementThe authors have declared no competing interest.View Full Text
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Measuring Transcranial Magnetic Stimulation-Induced Electric Fields in Anatomically and Conductively Accurate Rat Head Phantoms 97%
- Magnetic Temporal Interference for Noninvasive Focal Brain Stimulation 95%
- Non-invasive stimulation with Temporal Interference: Optimization of the electric field deep in the brain with the use of a genetic algorithm 95%
Similar papers in this journal
- Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T 99%
- Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants 97%
- Detailed measurements and simulations of electric field distribution of two TMS coils cleared for obsessive compulsive disorder in the brain and in specific regions associated with OCD 95%
Similar papers in this journal
Similar papers in this journal
- Multi-locus transcranial magnetic stimulation system for electronically targeted brain stimulation 95%
- Sound comparison of seven TMS coils at matched simulation strength 92%
- Adaptive current-flow models of ECT: Explaining individual static impedance, dynamic impedance, and brain current delivery 92%
Similar papers in this journal
- Improved 7 Tesla Transmit Field Homogeneity with Reduced Electromagnetic Power Deposition Using Coupled Tic Tac Toe Antennas 95%
- Individual head models for estimating the TMS-induced electric field in rat brain 93%
- Improved spatio-temporal measurements of visually evoked fields using optically-pumped magnetometers 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.