Performance and health economic evaluation of the Mount Sinai COVID-19 serological assay identifies modification of thresholding as necessary to maximise specificity of the assay
Rushworth, S. A.; Johnson, B. B.; Ashurst, K.; Davidson, R.; Paddy, P.; Mistry, J. J.; Moore, J. A.; Hellmich, C.; Edwards, D. R.; Afonso, D. D.; Xydopoulos, G.; Goodwin, R.; Gomez, J.; Prakash, R.; Dervisevic, S.; Fordham, R.; Bowles, K.; Smith, J.
Show abstract
We evaluated the FDA approved SARS-CoV-2 immunoassay (developed at Mount Sinai, by Krammer and colleagues) for the identification of COVID-19 seroconversion and potential cross-reactivity of the assay in a United Kingdom (UK) National Health Service (NHS) hospital setting. In our set up cohort we found that the SARS-CoV-2 IgG was detectable in 100% of patients tested 14 days post positive COVID-19 nucleic acid test. Serum samples taken from pregnant women in 2018 were used as a negative control group with zero false positives. We also analysed samples from patients with non-COVID-19 viral infections, paraproteinaemia or autoantibodies and found false positive results in 6/179. Modification of the sensitivity threshold to five standard deviations from the mean of the control group eliminated all false positive result in the set up cohort. We confirmed the validity of the test with a revised threshold on an independent prospective validation cohort of patient samples. Taking data from both cohorts we report a sensitivity of the Mount Sinai assay of 96.6% (28/29) and specificity of 100% (299/299) using a revised threshold cut-off, at a time point at least 14 days since the diagnostic antigen test. Finally, we conducted a health economic probabilistic sensitivity analysis (PSA) on the costs of producing the tests, and the mean cost we estimate to be 13.63 pounds sterling (95%CI 9.63 - 18.40), allowing its cost effectiveness to be tested against other antibody tests. In summary, we report that the Mount Sinai IgG ELISA assay is highly sensitive test for SARS-Cov-2 infection, however modification of thresholding was required to minimise false positive results.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Emergence of SARS-CoV-2 Alpha (B.1.1.7) variant, infection rates, antibody seroconversion and seroprevalence rates in secondary school students and staff: active prospective surveillance, December 2020 to March 2021, England 91%
- Kinetics and performance of the Abbott Architect SARS-CoV-2 IgG antibody assay 91%
- The performance of the SARS-CoV-2 RT-PCR test as a tool for detecting SARS-CoV-2 infection in the population: A survey of routine laboratory RT-PCR test results from the region of Münster, Germany 91%
Similar papers in this journal
- SARS-CoV-2 Antibody Lateral Flow Assay for antibody prevalence studies following vaccine roll out: a Diagnostic Accuracy Study 93%
- Impact of baseline cases of cough and fever on UK COVID-19 diagnostic testing rates: estimates from the Bug Watch community cohort study 92%
- Antibody testing for COVID-19: A report from the National COVID Scientific Advisory Panel 92%
Similar papers in this journal
- Going beyond clinical routine in SARS-CoV-2 antibody testing - A multiplex corona virus antibody test for the evaluation of cross-reactivity to endemic coronavirus antigens 92%
- Substantial underestimation of SARS-CoV-2 infection in the United States due to incomplete testing and imperfect test accuracy 91%
- A translational multiplex serology approach to profile the prevalence of anti-SARS-CoV-2 antibodies in home-sampled blood 90%
Similar papers in this journal
- Diagnostic accuracy of three prevailing rapid antigen tests for detection of SARS-CoV-2 infection in the general population: cross sectional study 93%
- Quantifying the potential value of antigen-detection rapid diagnostic tests for COVID-19: a modelling analysis 90%
- Determinants of pre-vaccination antibody responses to SARS-CoV-2: a population-based longitudinal study (COVIDENCE UK) 90%
Similar papers in this journal
- Evaluation of SARS-CoV-2 Antibody Point of Care Devices in the Laboratory and Clinical Setting 94%
- An optimized stepwise algorithm combining rapid antigen and RT-qPCR for screening of COVID-19 patients 92%
- Evaluation of the accuracy and ease-of-use of Abbott PanBio - A WHO emergency use listed, rapid, antigen-detecting point-of-care diagnostic test for SARS-CoV-2 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.