Is the Current N95 Respirator Filtration Efficiency Test Sufficient for Evaluating Protection Against Submicrometer Particles Containing SARS-CoV-2?

Cai, C.; Floyd, E. L.; Aithinne, K. A.; Oni, T.

2020-06-09 occupational and environmental health
10.1101/2020.05.14.20102327 medRxiv
Show abstract

The National Institute of Occupational Safety and Health procedure No. TEB-APR-STP-0059 recommend of measuring the respirator filtration efficiency using sodium chloride aerosol with count median diameter of 75 nm {+/-} 20 nm and geometric standard deviation [≤]1.86. This study showed that this method would overestimate the respirators ability to protect against submicrometer particles. In this study, we converted both mobility diameter and equivalent volume diameter to aerodynamic diameter for comparison. The results showed that one unqualified KN95 respirator (with the filtration efficiency of 72%{+/-}3% for [≥]300 nm sodium chloride aerosol) still passed the test with a measured overall filtration efficiency of 98%{+/-}3%, due to its larger most penetrating particle size compared to the typical N95 respirator. In addition, after three cycle H2O2 plasma vaporous sterilizations, the most penetrating particle size for the N95 grade respirators also shifted to 250 nm - 500 nm, in which size the particles carried the peak concentration of the SARS-CoV-2 in hospitals. This size shift caused the significant difference between the size specific (250 nm - 500 nm) filtration efficiency and overall filtration efficiency using the same NaCl test aerosol. For example, after three cycle H2O2 plasma vaporous sterilizations, the size specific filtration efficiency of the N95 was 55%{+/-}2%, however, the measured overall filtration efficiency was still 86%{+/-}5%. The size Specific filtration efficiency of the KN95 was 69%{+/-}2%, but, the measured overall filtration efficiency was still 90%{+/-}3%. In order to protect health care personnel adequately, we recommend increasing the test aerosol size, and measuring the size specific filtration efficiency to evaluate the N95 alternatives (e.g. KN95), and the reuse of N95 level respirators. In addition, multi-cycle sterilization with ultraviolet germicidal irradiation appears to have fewer negative effects than H2O2.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

1
PLOS ONE
5266 papers in training set
Top 6%
23.8%
2
International Journal of Environmental Research and Public Health
128 papers in training set
Top 0.1%
19.7%
3
Indoor Air
10 papers in training set
Top 0.1%
8.4%
50% of probability mass above
4
Scientific Reports
3612 papers in training set
Top 19%
5.2%
5
Photochemistry and Photobiology
10 papers in training set
Top 0.1%
4.3%
6
Frontiers in Public Health
148 papers in training set
Top 2%
3.4%
7
Environmental Science & Technology Letters
21 papers in training set
Top 0.1%
2.9%
8
The Innovation
13 papers in training set
Top 0.1%
2.9%
9
Infection Control & Hospital Epidemiology
17 papers in training set
Top 0.1%
2.8%
10
Chemical Research in Toxicology
10 papers in training set
Top 0.1%
2.6%
11
Journal of Hospital Infection
29 papers in training set
Top 0.1%
2.3%
12
Annals of the American Thoracic Society
11 papers in training set
Top 0.1%
2.3%
13
American Journal of Infection Control
12 papers in training set
Top 0.1%
2.3%
14
BMC Research Notes
33 papers in training set
Top 0.3%
1.8%
15
Frontiers in Bioengineering and Biotechnology
98 papers in training set
Top 1.0%
1.8%
16
Science of The Total Environment
186 papers in training set
Top 3%
1.0%
17
JAMA Network Open
130 papers in training set
Top 3%
0.9%
18
Environmental Research
49 papers in training set
Top 1%
0.6%
19
Remote Sensing
10 papers in training set
Top 0.2%
0.5%
20
PLOS Global Public Health
344 papers in training set
Top 9%
0.5%
21
International Journal of Infectious Diseases
129 papers in training set
Top 4%
0.5%
22
Cureus
68 papers in training set
Top 5%
0.5%