Back

eCovSens-Ultrasensitive Novel In-House Built Printed Circuit Board Based Electrochemical Device for Rapid Detection of nCovid-19

Mahari, S.; Roberts, A.; Shahdeo, D.; Gandhi, S.

2020-04-25 bioengineering
10.1101/2020.04.24.059204 bioRxiv
Show abstract

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 or nCovid-19) outbreak has become a huge public health issue due to its rapid transmission and global pandemic. Currently, there are no vaccines or drugs available for nCovid-19, hence early detection is crucial to help and manage the outbreak. Here, we report an in-house built biosensor device (eCovSens) and compare it with a commercial potentiostat for the detection of nCovid-19 spike antigen (nCovid-19Ag) in spiked saliva samples. A potentiostat based sensor was fabricated using fluorine doped tin oxide electrode (FTO) with gold nanoparticle (AuNPs) and immobilized with nCovid-19 monoclonal antibody (nCovid-19Ab) to measure change in the electrical conductivity. Similarly, eCovSens was used to measure change in electrical conductivity by immobilizing nCovid-19 Ab on screen printed carbon electrode (SPCE). The performances of both sensors were recorded upon interaction of nCovid-19Ab with its specific nCovid-19Ag. Under optimum conditions, the FTO based immunosensor and eCovSens displayed high sensitivity for detection of nCovid-19Ag, ranging from 1 fM to 1 M. Our in-house developed device can successfully detect nCovid-19Ag at 10 fM concentration in standard buffer that is in close agreement with FTO/AuNPs sensor. The limit of detection (LOD) was found to be 90 fM with eCovSens and 120 fM with potentiostst in case of spiked saliva samples. The proposed portable eCovSens device can be used as a diagnostic tool for the rapid (within 10-30 s) detection of nCovid-19Ag traces directly in patient saliva in a non-invasive manner.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

1
Biosensors and Bioelectronics
52 papers in training set
Top 0.1%
41.4%
2
ACS Sensors
45 papers in training set
Top 0.1%
15.1%
50% of probability mass above
3
Sensors
39 papers in training set
Top 0.2%
7.2%
4
ACS Nano
99 papers in training set
Top 1%
2.7%
5
Chemical Engineering Journal
10 papers in training set
Top 0.1%
2.5%
6
Scientific Reports
3102 papers in training set
Top 52%
2.0%
7
Water Research
74 papers in training set
Top 0.8%
1.8%
8
PLOS ONE
4510 papers in training set
Top 56%
1.6%
9
Analytical Chemistry
205 papers in training set
Top 2%
1.6%
10
Talanta
12 papers in training set
Top 0.4%
1.4%
11
Nano Letters
63 papers in training set
Top 2%
1.4%
12
Advanced Healthcare Materials
71 papers in training set
Top 1%
1.4%
13
Advanced Science
249 papers in training set
Top 14%
1.3%
14
Analytica Chimica Acta
17 papers in training set
Top 0.4%
1.0%
15
Nature Communications
4913 papers in training set
Top 58%
1.0%
16
ACS Omega
90 papers in training set
Top 3%
0.9%
17
ACS Applied Bio Materials
21 papers in training set
Top 0.6%
0.9%
18
ACS Biomaterials Science & Engineering
37 papers in training set
Top 0.8%
0.9%
19
The Analyst
15 papers in training set
Top 0.5%
0.8%
20
ACS Chemical Neuroscience
60 papers in training set
Top 2%
0.8%
21
Nanoscale Advances
13 papers in training set
Top 0.5%
0.8%
22
Advanced Functional Materials
41 papers in training set
Top 2%
0.8%
23
ACS Applied Materials & Interfaces
39 papers in training set
Top 1%
0.5%
24
Materials Today Bio
18 papers in training set
Top 0.7%
0.5%
25
Lab on a Chip
88 papers in training set
Top 1%
0.5%