BackgroundComputed tomography (CT), by its nature, imparts a high dose of ionising radiation to patients being imaged. Diagnostic Reference Levels (DRLs) are used extensively in research but are also used in practice to establish if local imaging protocols have been optimised. AimTo audit effective dose (ED) at CT for four commonly performed examinations performed with a modern multidectector 64 slice CT (MDCT) system at large tertiary care centre by comparison with current international reference standards Methods800 consecutive studies of CT brain, cervical spine, thorax and abdomen-pelvis were examined. All patients were imaged on 64-slice MDCT with study-specific protocols. Dose descriptors were extracted from image dose reports. ED was calculated using dose-length product conversion coefficients for all patients. Data was collated with Irish national and local DRLs, and published international point values. ResultsED range at CT abdomen-pelvis of 2.03-26.04 mSv (mean 8.041 mSv) was 28.5% above the national DRL (9 mSv) and 26% above the local DRL (9.75 mSv). ED at CT thorax of 2.46-10.09 mSv (5.061 mSv) was 3.5% greater than local DRL (8.4mSv) and 42.5% greater than the national DRL (5.46 mSv). ED at CT brain of 2.25-8.08 mSv (3.075 mSv) was 100% above both the local (1.98 mSv) and national (2.06 mSv) DRLs. CT cervical spine ED of 1.49-21.94 mSv (5.14 mSv) was 79% greater than the local (3.07 mSv) and 100% greater than the national DRL (1.42 mSv). ConclusionsAll studies exceed national DRLs. A significant optimisation potential is noted, in particular, for studies involving the head and cervical spine. A further review of study protocols is necessary to facilitate optimisation of total study radiation dose.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Precise dose verification in proton therapy using Positron Emission Tomography. 95%
- Patient-derived PixelPrint phantoms for evaluating clinical imaging performance of a deep learning CT reconstruction algorithm 95%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 92%
Similar papers in this journal
- National diagnostic reference levels for digital diagnostic and screening mammography in Uganda. 94%
- Predictive factors for the development of peritumoral brain edema after LINAC-based radiation treatment in patients with intracranial meningioma 93%
- Internal calibration for opportunistic computed tomography muscle density analysis 93%
Similar papers in this journal
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 92%
- Cell lines of the same anatomic site and histologic type show large variability in intrinsic radiosensitivity and relative biological effectiveness to protons and carbon ions 92%
- Non-Invasive monitoring of normal tissue radiation damage using quantitative ultrasound spectroscopy 91%
Similar papers in this journal
Similar papers in this journal
- Detection of Alteration in Carotid Artery Volumetry Using Standard-of-care Computed Tomography Surveillance Scans Following Unilateral Radiation Therapy for Early-stage Tonsillar Squamous Cell Carcinoma Survivors: A Cross-Sectional Internally-Matched Carotid Isodose Analysis 92%
- Morphological changes after cranial fractionated photon radiotherapy: localized loss of white matter and grey matter volume with increasing dose 92%
- Personalized volume-deescalated elective nodal irradiation in oropharyngeal squamous cell carcinoma (DeEscO): a study protocol 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.